Travel Limit Magnet Installation
The Estate Slide operator is supplied with a sensor, by detecting the transit of two magnets secured to the top of the
rack, it commands gate movement to stop.
1.
Position the magnets on the rack as shown below.
2.
Power up the control board and enter the diagnostic mode (Chapter 10)
3.
Manually take the gate to the open position, but allow a space of 2
cm from the travel limit mechanical stop position. Slide the magnet
on the rack until you see that LED 1 on the control board goes off.
Tighten the magnet’s securing screws.
4.
Manually take the gate to the closed position, but allow a space of 2
cm from the travel limit mechanical stop position. Slide the magnet
on the rack until you see that LED 1 on the control board goes off.
Tighten the magnet’s securing screws.
5.
Re
-
lock the operator.
6.4