1 1
E124 24
532365 - Rev.A
0 0 0 0 1
Open A_1 Open B_1
0 0 0 1 1
Open A_1 Open B_2
0 0 1 0 1
Open A_1 Stop
0 0 1 1 1
Open A_1 Close
0 1 0 0 1
Open A_2 Open B_1
0 1 0 1 1
Open A_2 Open B_2
0 1 1 0 1
Open A_2 Stop
0 1 1 1 1
Open A_2 Close
1 0 0 0 1
Open A_3 Open B_3
1 0 0 1 1
Open A_3 Open B_4
1 0 1 0 1
Open A_3 StopNC_1*
1 0 1 1 1
Open A_3 Close
1 1 0 0 1
Open A_4 Open B_3
1 1 0 1 1
Open A_4 Open B_4
1 1 1 0 1
Open A_4 StopNC_2*
1 1 1 1 1
Open A_4 Close
ON
1 2 3 4 5
0 0 0 0 0
Open A_1
0 0 0 1 0
Open A_2
0 0 1 0 0
Open A_3
0 0 1 1 0
Open A_4
0 1 0 0 0
Open A_5
0 1 0 1 0
Stop
0 1 1 0 0
Stop NC_1*
0 1 1 1 0
Stop NC_2*
1 0 0 0 0
Close
1 0 0 1 0
Open B_1
1 0 1 0 0
Open B_2
1 0 1 1 0
Open B_3
1 1 0 0 0
Open B_4
1 1 0 1 0
Open B_5
1 1 1 0 0
/
1 1 1 1 0
/
ON
1 2 3 4 5
BUS 2easy BUS 2easy BUS 2easy
2EASY
Tr
ansla
tion of the orig
inal instruc
tions
ENGLISH
Connecting to the 2EASY terminal board
Do not exceed the maximum load of 500 mA.
The overall length of the BUS 2easy cables must not exceed 100 m.
7.1 BUS 2EASY DEVICES
BUS 2EASY CONTROL DEVICES
!
Do not use the BUS 2easy line for emergency stop
commands.
L
BUS 2easy control devices require E124 firmware version
FW 3.2
or later.
1. Configure the DIP switches on the device to assign
1 o 2 commands.
-
DIP switches for BUS 2easy
commands.
IMPORTANT
: a command (e.g.: OPEN A_1) can be used with only
one of the BUS 2easy control devices connected to the board. Before
adding a BUS 2easy control device, check the DIP switches of the
devices that are already present.
When multiple devices are connected, assigning the same BUS 2easy
command to more than one control device generates an error and
prevents the automation from working (
CONFLICT
).
Example
There are 5 commands available for OPEN A: OPEN A_1…
OPEN A_5. In order to have OPEN A on two different connected
devices, use an OPEN A_1 and an OPEN A_2. To add additional
devices for OPEN A, use OPEN A_3 ... and so on.
2. Install the devices following the instructions sup-
plied with them.
3. Connect to the
2EASY
terminal board using two
cables without polarity.
4. Register the BUS 2easy devices that are connected
(see § specific section).
-
note
: BUS 2easy registration is also carried out via
the SETUP.
5
BUS 2easy command DIP switches
Key: 0=OFF , 1=ON
DIP switch 5 enables the device for 1 (OFF )command or 2 (ON)
commands
* Stop NC also generates a stop when the device is disconnected. If
you do not require this function, use one Stop.