8
ENGLISH
Display
Function
Default
0
Default
1
Default
2
Default
3
FA
TRAVEL-LIMIT STOP AT OPENING:
The use of travel limit stops at opening enables us to
indicate the point after which the equipment search for the
mechanical stop point (
01
,
0 2
,
03
) or to immediately stop
the automated system (
04
,
0 5
,
06
):
00
= no travel limit device at opening for both leaves
0 1
= searches for stop point of leaf and 2
02
= searches for stop point of leaf
03
= searches for stop point of leaf 2
04
= stops movement of leaf and 2
05
= stops movement of leaf
06
= stops movement of leaf 2
By changing limit switches setting,
the letters
S0
together with the SETUP
(DL18) LED flash on the display, to
indicate that the SETUP must be
executed when exiting the programming
menu. If the limit switch is used, the
SOFT-TOUCH function, if enabled, is not
carried out
.
00 00 00 00 00 00
FC
TRAVEL-LIMIT STOP AT CLOSING:
The use of travel limit stops at closing enables us to indicate the
point after which the equipment search for the mechanical stop
point (
01
,
0 2
,
03
) or to immediately stop the automated
system (
04
,
0 5
,
06
):
00
= no travel limit device at closing for both leaves
0 1
= searches for stop point of leaf and 2
02
= searches for stop point of leaf
03
= searches for stop point of leaf 2
04
= stops movement of leaf and 2
05
= stops movement of leaf
06
= stops movement of leaf 2
By changing limit switches setting,
the letters
S0
together with the SETUP
(DL18) LED flash on the display, to
indicate that the SETUP must be
executed when exiting the programming
menu. If the limit switch is used, the
SOFT-TOUCH function, if enabled, is not
carried out
.
00 00 00 00 00 00
SE
OBSTACLE SENSITIVITY:
Change this parameter to set the time after which, in
the event of an obstacle, the board commands leaf
reversal, or leaf stop if the leaves are within the space
for the travel limit search (see parameter
rB
).
The fourth consecutive obstacle detected in the same
direction is considered as the travel stop and the leaf
stops in that position.
01
= minimum sensitivity
10
= maximum sensitivity
10 08 08 07 08 07
US
ULTRA-SENSITIVITY:
This function activates an obstacle detection system,
based on the control of the variation of the current
absorbed by the motor, causing immediate leaf
reversal.
Y
= active
no
= excluded
no no no no no no
Display
Function
Default
0
Default
1
Default
2
Default
3
Default
4
Default
5