5
ENGLISH
PA
PAUSE TIME A:
Pause time following a
TOTAL
opening command. It has
only effect if a logic with pause time was selected. Can
be adjusted from 0 to 59 sec. in one-second steps.
Next, the viewing changes in minutes and ten seconds
(separated by a dot) and time is adjusted in 0-second
steps, up to the maximum value of
9.5
minutes.
E.g.: if the display shows
2.5
, the pause time will be 2
min. and 50 sec.
Other more detailed programming
possibilities are feasible by programming
with a PC (see dedicated instructions).
20 20 20 20 20 20
Pb
PAUSE TIME B:
Pause time following a
PARTIAL
opening command. It has
only effect if a logic with pause time was selected. Can
be adjusted from 0 to 59 sec. in one-second steps.
Next, the viewing changes in minutes and ten seconds
(separated by a dot) and time is adjusted in 0-second
steps, up to the maximum value of
9.5
minutes.
E.g.: if the display shows
2.5
, the pause time will be 2
min. and 50 sec.
Other more detailed programming possibilities
are feasible by PC programming (see
dedicated instructions).
20 20 20 20 20 20
F1
MOTOR 1 POWER:
Adjusts the maximum power level of motor .
01
= minimum power
50
= maximum power
Other more detailed programming
possibilities are feasible by programming
with a PC (see dedicated instructions).
If the power value is changed, we
advise you to execute a new SETUP (see
parag.10.1)
25 25 25 40 25 35
F2
MOTOR 2 POWER:
Adjusts the maximum power level of motor 2.
01
= minimum power
50
= maximum power
Other more detailed programming
possibilities are feasible by programming
with a PC (see dedicated instructions).
If the power value is changed, we
advise you to execute a new SETUP (see
parag.10.1)
25 25 25 40 25 35
SP
SPEED:
Adjusts the motion speed of the motors. There are 0
levels. The value is relative and not absolute, because
the speed value refers to the weight of the leaf measured
during the SETuP cycle
0 1
= minimum speed
1 0
= maximum speed
Other more detailed programming
possibilities are feasible by programming
with a PC (see dedicated instructions).
08 08 08 08 08 08
Display
Function
Default
0
Default
1
Default
2
Default
3
Default
4
Default
5