20
ENGLISH
Display
Fucntion
Default
0
Default
1
Default
2
Default
3
Default
4
Default
5
o2
OUT 2:
used for setting the OuT output (open collector N.O.):
00
= Always active
01
= FAIL-SAFE
02
= INDICATOR LIGhT (off when closed, lighted during
opening and open/pause, flashes during closing)
03
= COuRTESY LIGhT (see next parameter)
04
= ALARM on BATTERY operation
05
= gate OPEN or in PAuSE
06
= gate CLOSED
07
= gate MOVING
08
= gate in EMERGENCY status
09
= gate OPENING
10
= gate CLOSING
11
= ELECTRIC LOCK command before CLOSuRE (you
have to interface with relay 24V – 00mA)
12
= safety device ACTIVE
13
= ‘TRAFFIC LIGhTS’ function (activates during OPENING
and when gate OPEN)
14
= timed output; it can be activated from the second
radio channel OMNIDEC (see next parameter)
15
= this output can be activated from the second
radio channel OMNIDEC (step-by-step function)
16
= electric lock before an OPENING (you have to
interface with relay 24V – 00mA)
Other more detailed programming pos-
sibilities are feasible by programming with
a PC (see dedicated instructions).
02 02 02 02 02 02
t2
TIMING OUT 2 (only visible if at the previous step
o2
the item
03
-
11
-
14
-
16
was selected):
Adjusts the timing of output OuT 2 if a timed function from
1
to
99
minutes in -minute step was selected for the
functions
03
-
14
and from
1
to
99
seconds in -second
step for the functions
11
-
16
.
02 02 02 02 02 02
X
RESET and X-COM RADIO MODULE ACQUISITION:
The X-COM module is used for radio communication between
board and PC. Before enabling a communication, the X-COM
module must be configured.
If
no
is displayed when entering this menu, this means that
the X-COM module has not yet been configured or fitted. To
start the configuration procedure, fit the module in the MA-
XCOM connector on the board and hold down push-
for 5 sec.
Y
will appear on the display and the flashing light will
operate. The configuration procedure must then be terminated
from the PC. If
Y
is shown when you enter this menu, this means
that the X-COM module has been configured and is ready to
communicate. The X-COM module can be reset by holding
down the – key for 5 seconds.
Y
= X-COM module enabled to function.
no
= no X-COM module fitted or configured.
no no no no no no