background image

INSTRUCTION MANUAL MT, MA2, MK2, M10 DRIVE UNIT

18

•  Side installation

Mounting plate

1

The mounting plate is not manufactured by FAAC.

The measurement from the floor or other permanent entry level to the lower 

edge of the mounting plate should be at least 2,550 mm.

The dimensions of the mounting plate should be 200 mm x 400 mm and 

it should be at least 8 mm thick. It must be positioned according to the 

enclosed assembly drawing. The mounting plate is to be anchored so that it 

can withstand a torque of 2,000 Nm. 

Example: Siporex wall - through-going M10 bolts are used. 

Concrete – 10 mm resin anchor.    

Steel building – square tube onto a fixed building structure.  

The mounting plate is also welded onto the gate surround.

Drive arm

2

Install the drive arm by removing the bolt and washer / 

retaining ring on the output shaft from the drive unit and 

pressing the arm into place. 

Then reinstall the bolt and washer. 

Summary of Contents for DAAB MT

Page 1: ...Issue 1 USER INSTRUCTIONS DAAB DRIVE UNIT MT MK2 MA2 M10 FAAC Nordic AB BOX 125 SE 284 22 PERSTORP SWEDEN TEL 46 435 77 95 00 FAX 46 435 77 95 29 www faac se R e v i s i o n 3...

Page 2: ...14 Drive arm 14 Installing the drive unit 15 Drive unit MT 16 Function description 16 Design and function 16 Dimensions 16 Technical specification 17 Electric motors 17 Gears 17 Installation and comm...

Page 3: ...dards Immunity for industrial environments SS EN 61000 6 3 Electromagnetic compatibility EMC Part 6 3 Generic standards Emission standard for residential commercial and light industrial environment Th...

Page 4: ...the relevant precaution is not taken WARNING This means that there is a risk of bodily injury or damage to the machine if the relevant precaution is not taken NOTE This means that important informatio...

Page 5: ...must not be removed or made illegible The identification plate contains the following information Art no Part number Ser no The serial number of the drive unit used in all communication with FAAC Nord...

Page 6: ...MA2 MK2 Function description Design and function Dimensions 4 2 1 2 6 7 1 4 0 5 3 0 290 290 421 267 140 530 290 Bracket V belt Terminal block Limit switches Limit cams Gearbox Base plate Disengagement...

Page 7: ...te duty cycle In practice the motor is not subject to full load for more than one second just as it starts The motor is available both with and without an integrated thermal switch If the motor has a...

Page 8: ...ick It must be positioned according to the enclosed assembly drawing The mounting plate is to be anchored so that it can withstand a torque of 2 000 Nm Lightweight concrete wall for example through go...

Page 9: ...e pivot point as possible as this provides the best geometry Screw the gate mounting into place using two M8 bolts and washers Top mounting Bracket mounting plate 1 Positioned centrally above the gate...

Page 10: ...the arm into place Then reinstall the bolt and washer retaining ring Gate mounting 4 Screw the gate mounting into place using two M8 bolts according to the assembly drawing Link arm 5 Position the lin...

Page 11: ...nce with a separate assembly drawing Then weld the motor plate onto the mounting plate Drive arm 2 Install the drive arm by removing the bolt and washer retaining ring on the output shaft from the dri...

Page 12: ...ed Mounting plate in the chapter Installation and commissioning Side installation 5 Screw the bracket into place on the mounting plate using four M10 bolts Adjust the swing arm so that it is always ho...

Page 13: ...ween the drive arm and swing arm using M12 bolts and washers 9 Adjust it by undoing one bolt and then screwing the arm out or in at the swing arm mounting 10 Adjust the outer link arm by unscrewing th...

Page 14: ...plate horizontally according to the assembly drawing Then weld the motor plate onto the mounting plate Drive arm 2 Install the drive arm by removing the bolt and washer retaining ring on the output sh...

Page 15: ...epending on the angle at which it is positioned Viewed from the left this is 90 100 and 110 degrees The angle to be used is indicated in the assembly drawing supplied with the unit 1 Insert the drive...

Page 16: ...UNIT 16 Drive unit MT Function description Design and function Dimensions 400 257 483 207 100 400 257 483 207 100 Bracket Terminal block Limit switches Limit cams Gearbox Base plate Disengagement Driv...

Page 17: ...load in continuous operation S3 Intermittent operation The motor must not be subject to full load for more than 25 of the 10 minute duty cycle In practice the motor is not subject to full load for mor...

Page 18: ...t 8 mm thick It must be positioned according to the enclosed assembly drawing The mounting plate is to be anchored so that it can withstand a torque of 2 000 Nm Example Siporex wall through going M10...

Page 19: ...nting and drive arm The lateral position of the gate mounting can be determined when the gate is fully closed and the drive arm and link arm are in line The gate mounting should be as close to the piv...

Page 20: ...ntre the plate horizontally above the gate opening Height dimensions in accordance with a separate assembly drawing Then weld the motor plate onto the mounting plate Drive arm 3 Install the drive arm...

Page 21: ...M10 DRIVE UNIT 21 Link arm 5 Position the link arm between the drive arm and gate mounting Screw it into place using M12 bolts and washers 6 Adjust it by undoing one bolt and then screwing the arm ou...

Page 22: ...ll the drive arm by removing the bolt and washer retaining ring on the output shaft from the drive unit and pressing the arm into place Then reinstall the bolt and washer retaining ring Gate mounting...

Page 23: ...orizontal 6 Adjust the mounting using the four set screws 7 Screw in the short link arm between the outer swing arm mounting and the gate mounting using M12 bolts and washers Link arm 8 Screw in the l...

Page 24: ...INSTRUCTION MANUAL MT MA2 MK2 M10 DRIVE UNIT 24 10 Adjust the outer link arm by unscrewing the bolt on the mounting and then inserting it into the oblong groove in the drive arm...

Page 25: ...hat it does not press too hard on the surround or does not open completely The leaves of the gate must line up with each other in the closed position which is important if there is a solenoid lock or...

Page 26: ...al work WARNING All electrical work must be carried out by a qualified electrician NOTE Check that the supply voltage and motor voltage are the same Engaging the electric motor U1 V1 W1 W2 U2 V2 3 pha...

Page 27: ...or or gate supplier If instructions are missing a check of the safety functions shall be performed twice a year This must be documented in a log book Preventive maintenance must be performed depending...

Page 28: ...e control cabinet Fault search In the event of a blockage If the door gate cannot be operated manually using one of the normal control devices use the manual release see the chapter on disengagement D...

Page 29: ...INSTRUCTION MANUAL MT MA2 MK2 M10 DRIVE UNIT 29...

Page 30: ......

Reviews: