background image

INSTRUCTION MANUAL DAAB VEHICLE DETECTOR DB402

Revision 7 

5

Suggested vehicle loop layout

DOUBLE HINGED GA

TE

SINGLE HINGED GA

TE

4-SEC

TION FOLDING DOOR

2-SEC

TION FOLDING DOOR

Loop is not t

wist

ed-pair

Connec

tor t

wist

ed-pair

 or shielded cable

SA

W CUT SL

O

T

Concr

ete

Asphalt

Instruc

tion f

or la

ying v

ehicle loops f

or ga

tes

,

doors and bar

riers

.

A

ll dimensions in the table belo

w ar

e in mm.

For other inf

or

ma

tion such as the number of tur

ns in

the loop

, see user instruc

tions f

or v

ehicle det

ec

tor

.

G

at

e-

door

width 

Bar

rier length

G

at

es & D

oors

Sliding ga

te

, Bar

rier

Sliding ga

tes

Bar

riers

SLIDING GA

TE

Bar

rier

Suggestion f

or v

ehicle

loop la

yout

Summary of Contents for DAAB DB402

Page 1: ...or DAAB automatic control unit EP104 EP105 INSTRUCTION MANUAL DAAB VEHICLE DETECTOR DB402 FAAC Nordic AB BOX 125 SE 284 22 PERSTORP SWEDEN 46 435 77 95 00 support faac se www faac se R e v i s i o n 7...

Page 2: ...omatic control units Two vehicle loops can be connected to this card Function with activated loop is controlled by the d channels in the automatic control unit The vehicle sensor operates at two diffe...

Page 3: ...re handling PCB 2 Disconnect the power to the automatic control unit 3 Screw the DB402 card into place on the spacers on the automatic control unit using two M4x6 screws 4 Connect cable to LOOP connec...

Page 4: ...that the insulation is not damaged If necessary fix the loop in place before backfilling the channel Before backfilling the channel test the loop with the vehicle concerned Loop placement To ensure go...

Page 5: ...d p a i r o r s h i e l d e d c a b l e SAW CUT SLOT Concrete Asphalt Instruction for laying vehicle loops for gates doors and barriers All dimensions in the table below are in mm For other informati...

Page 6: ...connected in series using input NC which is a potential free contact It is important to remember that the loops must be of equal circumference to achieve reliable function Indications There are two ye...

Page 7: ...Use can use this channel to activate loop based closing The value 1 activates loop based closing and 0 deactivates loop based closing d154 Type of loop closing This channel works with d151 to control...

Page 8: ...c closing or set the value to 3 to send a stop signal without automatic closing The automatic closing timer starts when the vehicle exits the loop d141 Safety during run on time This channel activates...

Page 9: ...2 on the loop in the closed position 00 50 03 d140 Safety function in closing movement 0 4 1 0 Disabled 1 Reverse 2 Stop with automatic restart of automatic closing 3 Stop without automatic restart o...

Page 10: ...input 0 6 0 0 Disabled normal opening closing function Programmable input has no function for LOOP1 1 Opening possible only if there is a signal at programmable input 1 2 Opening possible only if the...

Page 11: ...loop in the closed position 00 50 03 d240 Safety function in closing movement 0 4 1 0 Disabled 1 Reverse 2 Stop with automatic restart of automatic closing 3 Stop without automatic restart of automati...

Page 12: ...ut 0 6 0 0 Disabled normal opening closing function Programmable input has no function for LOOP2 1 Opening possible only if there is a signal at programmable input 1 2 Opening possible only if there i...

Page 13: ...INSTRUCTION MANUAL DAAB VEHICLE DETECTOR DB402 Revision 7 13 Notes...

Page 14: ......