background image

INSTRUCTION MANUAL DAAB VEHICLE DETECTOR DB402

Revision 7 

11

Vehicle loop 2

Note that the display of the d-channels is determined by the setting in C702 for EP105

No. 

Name

Range

Factory Setting

d200

Vehicle loop 2

0 - 1

0

0

Disabled

1

Enabled

d201

Loop reading x1

000 - 999

d202

Loop reading x1000

00 - 99

d203

Activation from passing vehicle

000 - 999

d210

Detection limit for a vehicle in the loop

05 - 99

15

d211

Difference between on and off in the loop

00 - 50

03

d220

Loop presence reset

000 and 005-240 

minutes

120

d221

Fast loop presence reset

00-99 seconds

00

d231

Compensation for activation from door half motor 1 on the 

loop in the closed position

00 - 50

03

d232

Compensation for activation from door half motor 2 on the 

loop in the closed position

00 - 50

03

d240

Safety function in closing movement

0 - 4

1

0

Disabled

1

Reverse

2

Stop with automatic restart of automatic closing

3

Stop without automatic restart of automatic closing, wait for new control signal

4

Safety only in open position. Used when the gate passes over the loop in the closing movement.

d241

Safety during run-on time or disengagement angle in closing 

movement.

0 - 1

1

0

Disabled

1

Activated according to d240

d242

Safety function in opening movement

0 - 4

0

0

Disabled

1

Reverse to fully closed

2

Stop with automatic restart of automatic closing

3

Stop without automatic restart of automatic closing, wait for new control signal

4

Safety only in closed position. Used when the gate passes over the loop in the opening movement.

d251

Loop closing

0 - 1

0

0

Disabled

1

Enabled

d254

Type of closing with loop

1 - 2

2

1

Close immediately when loop is clear

2

Open fully first, then close

Summary of Contents for DAAB DB402

Page 1: ...or DAAB automatic control unit EP104 EP105 INSTRUCTION MANUAL DAAB VEHICLE DETECTOR DB402 FAAC Nordic AB BOX 125 SE 284 22 PERSTORP SWEDEN 46 435 77 95 00 support faac se www faac se R e v i s i o n 7...

Page 2: ...omatic control units Two vehicle loops can be connected to this card Function with activated loop is controlled by the d channels in the automatic control unit The vehicle sensor operates at two diffe...

Page 3: ...re handling PCB 2 Disconnect the power to the automatic control unit 3 Screw the DB402 card into place on the spacers on the automatic control unit using two M4x6 screws 4 Connect cable to LOOP connec...

Page 4: ...that the insulation is not damaged If necessary fix the loop in place before backfilling the channel Before backfilling the channel test the loop with the vehicle concerned Loop placement To ensure go...

Page 5: ...d p a i r o r s h i e l d e d c a b l e SAW CUT SLOT Concrete Asphalt Instruction for laying vehicle loops for gates doors and barriers All dimensions in the table below are in mm For other informati...

Page 6: ...connected in series using input NC which is a potential free contact It is important to remember that the loops must be of equal circumference to achieve reliable function Indications There are two ye...

Page 7: ...Use can use this channel to activate loop based closing The value 1 activates loop based closing and 0 deactivates loop based closing d154 Type of loop closing This channel works with d151 to control...

Page 8: ...c closing or set the value to 3 to send a stop signal without automatic closing The automatic closing timer starts when the vehicle exits the loop d141 Safety during run on time This channel activates...

Page 9: ...2 on the loop in the closed position 00 50 03 d140 Safety function in closing movement 0 4 1 0 Disabled 1 Reverse 2 Stop with automatic restart of automatic closing 3 Stop without automatic restart o...

Page 10: ...input 0 6 0 0 Disabled normal opening closing function Programmable input has no function for LOOP1 1 Opening possible only if there is a signal at programmable input 1 2 Opening possible only if the...

Page 11: ...loop in the closed position 00 50 03 d240 Safety function in closing movement 0 4 1 0 Disabled 1 Reverse 2 Stop with automatic restart of automatic closing 3 Stop without automatic restart of automati...

Page 12: ...ut 0 6 0 0 Disabled normal opening closing function Programmable input has no function for LOOP2 1 Opening possible only if there is a signal at programmable input 1 2 Opening possible only if there i...

Page 13: ...INSTRUCTION MANUAL DAAB VEHICLE DETECTOR DB402 Revision 7 13 Notes...

Page 14: ......

Reviews: