12
INSTRUCTION MANUAL DAAB VEHICLE DETECTOR DB402
Revision 7
No.
Name
Range
Factory Setting
d260
Control function
0 - 1
0
0
Disabled
1
Open
d261
Type of control signal when activated
1 - 2
1
1
Pulse
2
Signal when loop is activated
d262
Half operation
1 - 3
3
1
Motor 1
2
Motor 2
3
Motors 1 and 2
d263
Limited opening
0 - 1
0
0
Disabled
1
Opening with limit switch according to set time in channel C412/C414 with EP104, L216/L226 with
EP105 or number of degrees in L116/L126 if encoder is used.
d270
Allows the opening function, via LOOP2, using a
programmable input.
0 - 6
0
0
Disabled, normal opening/closing function. (Programmable input has no function for LOOP2)
1
Opening possible only if there is a signal at programmable input 1
2
Opening possible only if there is a signal at programmable input 2
3
Opening possible only if there is a signal at programmable input 3
4
Opening possible only if there is a signal at programmable input 4
5
Opening possible only if there is a signal at programmable input 5
6
Opening possible only if there is a signal at programmable input 6
d275
Opening via loop after activation during set time, the loop
will not open the gate until it has been activated for the set
time.
0.0-9.9 seconds
0.0
d290
Interlock opening
0 - 1
0
0
Disabled
1
Sends a normal open signal to the remote door