![background image](http://html1.mh-extra.com/html/faac/c850/c850_user-manual_3127493013.webp)
C850
13
532015 - Rev.B
T
ranslation of the original instructions
ENGLISH
9 MAINTENANCE
We recommend checking system operation every six months,
with special attention to the safety devices (including the motor
thrust power, which must comply with the regulations in force)
and release devices.
10 REPAIRS
For repairs, contact an authorised FAAC Service Centre.
7 TESTING THE AUTOMATED SYSTEM
Once operator installation has been completed, carefully check
operation of all the connected accessories and safety devices.
Refit the transparent guard covering the control unit.
Fit the housing (Fig. 23 ref.
) and secure it using the four provided
screws (Fig. 23 ref.
).
Give the customer the “User’s Manual” and show how to correctly
operate and use the gearmotor, pointing out the areas of potential
danger of the automated system.
8 RELEASING/LOCKING THE OPERATOR
To manually move the gate, we recommend
cutting off electrical power. Rotating the knob
prevents any motor movement.
To release the gearmotor, proceed as follows:
1. Insert the provided key and turn clockwise (Fig. 24 ref.
).
2. Turn the release system clockwise until it reaches the mechanical
stop (Fig. 24 ref.
).
3. Open or close the gate manually.
Fig. 23
Fig. 24
To lock the gearmotor, proceed as follows:
1. Turn the release system anti-clockwise until it stops (Fig. 25 ref.
).
2. Turn the key anti-clockwise and then remove it from the lock (Fig.
25 ref.
).
Turning the release system knob clockwise will
prevent any movement of the motor.
Operator releasing and locking operations can
be carried out in any gate position.