AIRSLIDE
32
532225 - Rev.A
24
1
0,5
Nm
2
4
0,5
Nm
2
1
F1
F2
Tr
ansla
tion of the original instruc
tions
ENGLISH
7. ELECTRONIC INSTALLATION
F
ALWAYS DISCONNECT THE POWER SUPPLY before working on the
board. Turn power on only after having made all the electrical con-
nections and carried out the preliminary start-up checks.
Fuses
F1
230Vac power supply fuse
3.15 A
F2
Secondary power supply fuse
250 mA
N
BLUE
PE
YELLOW-GREEN
L
BROWN
RISKS
PERSONAL PROTECTIVE EQUIPMENT
REQUIRED TOOLS
2.5
7.1 PLATE AND E1AS BOARD
Connect the 230 VAC mains power supply to the terminal on the
board plate.