3. REQUIRED INSPECTIONS AND ARRANGEMENTS
3.2 ARRANGEMENT OF ELECTRICAL CABLES
!
Before performing any operation on the system, disconnect the
power supply.
The electrical system must be compliant with the regulations in force
in the Country of installation (EN 60335-1...)
The power mains of the automation system must be fitted with a
multi-pole power switch with a switch-contact gap of at least 3 mm. It
is advisable to use a 6A circuit breaker with a multi-pole power switch.
Ensure there is a residual current device with a 0.03 A threshold
upstream of the system.
Ensure the earthing system is constructed in a workmanlike manner
and connect the structure’s metal parts to it.
Arrange the electrical cables for connecting accessories and the
electrical power supply
3
.
Protect cables by means of suitable ducting.
!
Place control accessories within the automation’s visual range. These
devices must always be accessible, even with the door open.
Comply with the following heights from the ground:
- control accessories = minimum 150 cm
- emergency buttons = max 120 cm
3.1 PRELIMINARY INSPECTIONS
!
Prior to installation, check soundness of the load bearing masonry
structure and door. Perform any required work to assure:
- solidity, stability and absence of any risk of detachment or collapse
of the masonry structure, fixed door frame and automation
- level flooring, without any friction/hindrance to smooth leaf sliding
- absence of sharp edges (cutting hazard)
- absence of protruding parts (hooking/entrainment hazard)
230V~
6
1
2
3
external
internal
1
Monitored detector for internal opening and safe closing (XDT3)
included in the supply
2
Monitored detector for external opening and safe closing (XV1/XDT1)
optional accessory
3
SDK EVO
optional accessory
4
Key switch to lock theSDK EVO
optional accessory
5
Emergency/Key/OPEN control buttons
optional accessories
6
Power supply 230V~
7 Internal monitored detectors for safe opening (XBFA)
optional accessory