A1400 AIR RDT
14
532119 04 - Rev. C
Tr
ansla
tion of the original instruc
tions
ENGLISH
2.4 TECHNICAL SPECIFICATIONS
7
Technical specifications
MODEL
A1400 AIR RDT single leaf
A1400 AIR RDT double leaf
Length * [mm]
from 1750 to 4600
from 2200 to 6100
Depth * [mm]
234
234
Total depth with self-supporting beam * [mm]
289
289
Height * [mm]
100
100
Weight** [kg]
MIN. 25 - MAX 43
MIN. 31 - MAX. 55
No. of leaves
2
4
MAX weight of one leaf ***
The weight depends on the leaf dimensions:
L [m] Pmax [Kg]
≤
1.4
110+110
1.6 90+90
1.7 75+75
1.8 65+65
2.0 60+60
2.2 63+63
2.4 70+70
2.6 80+80
2.8 90+90
3.0 110+110
The weight is independent of leaf dimen-
sions:
60+60+60+60 [Kg]
Passage opening (Vp) [mm]
from 1100 to 3000
from 1400 to 3000
Beam length [mm]
Vp x 1.5 +100
Vp x 1.5 +100
Maximum framed leaf thickness [mm]
65
65
Power supply voltage
230 V~ (+6% -10% ) 50 Hz
230 V~(+6% -10% ) 50 Hz
MAX Absorbed power [W]
140
140
Use frequency
100 %
100 %
Main motor (with encoder)
powered at 36V
powered at 36V
Auxiliary motor (without encoder)
powered at 36V
powered at 36V
Max. accessories load
1A, 24V (excluding SDK EVO)
1A, 24V (excluding SDK EVO)
Time/date backup battery
Lithium CR2032 3V
Lithium CR2032 3V
Motion backup battery
NiMh 24V 1800mAh
NiMh 24V 1800mAh
Traction
by toothed belt
by toothed belt
Opening/closing speed adjustment (empty) [cm/s]
10... 75
20... 150
Partial opening adjustment
5%... 95% of total opening
5%... 95% of total opening
Pause time adjustment [s]
0... 30
0... 30
Night pause time adjustment [s]
0... 240
0... 240
Anti-crushing device
in opening/closing
in opening/closing
Protection sensors monitoring (EN 16005:2012)
can be bypassed
can be bypassed
Function Energy Saving
can be enabled
can be enabled
Drive Low Energy
can be enabled
can be enabled
Operating ambient temperature [°C]
-20... +55
-20... +55
Automation protection degree
IP 23 (internal use)
IP 23 (internal use)
* The dimensions and weight of the automation are specified excluding carriage and leaf overall dimensions, which are customisable
** For the specifications of weights in relation to automation length, see
28
.
*** The leaf weight is variable non proportional to L leaf dimension. This is connected to the opening speed which must remain constant regardless of leaf weight and size,
with reference to standard EN 16005:2012.