A1400 AIR RDT
100
532119 04 - Rev. C
Tr
ansla
tion of the original instruc
tions
ENGLISH
19.4 CLEANING
F
Before any maintenance operation, disconnect the mains power
supply and disconnect the emergency battery.
!
Before starting to clean, wait for the components subject to overheat-
ing to cool down.
DO NOT use detergents on optical devices and electronic displays
(e.g. photocell lenses).
Do not moisten parts. In particular, do not moisten electrical connec-
tions and components in any way.
NEVER use direct water and compressed air jets neither for cleaning
nor drying.
Ensure all components are dry after cleaning.
Use clean soft cloths to remove dust. Moisten the cloth to remove
dirt. Dry parts with clean, dry and soft cloths.
For parts that are hard to reach, use brushes with soft bristles.
Cleaning products for plastic material parts
With the exception of optical devices and electronic displays, water
and neutral detergent solutions are allowed (in the concentration
indicated by the manufacturer). Use detergents at ambient tempera-
ture (max. 30°C).
DO NOT use alkaline, acid or base solutions, benzene, acetic acid,
solvents of any kind: these products may damage the surfaces of
materials.
Cleaning products of steel or aluminium parts
Water and neutral detergent solutions are allowed (in the concentra-
tion indicated on the detergent packaging). 95% methylated spirit
diluted at 50%. In case of oily dirt, use 70% solutions of isopropyl
alcohol.
DO NOT use solutions of acetic acid, acid or base solutions, ethyl
alcohol.
19.5 FUNCTIONAL CHECKS
!
Connect power supply and emergency battery only after tidying up
the area.
In case of failures or malfunctioning, please refer to
73
and
76
.
Command some movements to check correct operation:
-
movements correctly executed, according to logics and settings
-
regular and smooth leaf movement
-
end of run slowing down correctly executed
-
drawing to the stops on opening and closing without any shocks
-
regular operation of motor block on Motor_1 (if present)
-
efficiency of emergency battery: disconnect mains power supply
and ensure the door opens and is locked open (safety condition)
-
efficiency of safety detectors (the radar field must be free and
adequately sized with respect to passage flow)
-
operation of EMERGENCY button (if present) and any other ac-
cessories installed.
20. WASTE DISPOSAL
After taking down the automation, dispose of it in compliance with
the material disposal regulations in force.
The constructive components must not be disposed of with household
waste but delivered to authorised disposal and recycling centres.