T21IF). The motor lock unit acts directly on the motor by locking it
mechanically.

Motor lock control

This controls if the motor lock operating efficiently and checks if the
door has actually closed. If necessary, the system is designed for
remote activation of an indicator-light or buzzer.

Emergency batteries

 (fig. 1 ref. 

)

In the event of a mains power cut, on-battery operation provides a
range of  30 minutes at 100% use frequency.
The battery charge status test is automatic and indicated by a LED.
The charge control board is designed for remote activation of a
'battery operating' signal.

Pair of side fixing  brackets  

(fig. 9)

3.2

Supplementary accessories

These are the  peripheral accessories for completing the automated
system.

-Miniswitch photocells
-T20E : outdoor key-operated selector switch
-T20I : flush-fitting key-operated selector switch
-T21EF : Outdoor key-operated selector switch designed for motor
release
-T21IF : Flush-fitting  key-operated selector switch designed for
motor release
-Detection sensors.
-SD Keeper

3.3

Door frame accessories

To facilitate adapting the door frame profile to the carriages and to
enable correct finishing of the installation, FAAC offers the following
series of articles:

Closing profile 

(fig. 2 ref. 

)

Available in natural and anodised aluminium versions, the profile is
used for closing the space between the mobile leaf and the wall on
which the head profile is secured.

Closing profile for free-standing facility 

(fig.3 ref. 

)

Available in anodised aluminium versions, the profile is used for
closing the space between the mobile leaf and the wall on which
the head profile is secured.

Brush for closing profiles 

(fig. 2 ref. 

 and  fig. 3 ref. 

)

Prevents dust reaching inside the head profile.

Pair of sliding blocks 

(fig.14 ref.

)

Supplied as a pair, they can be secured to the wall (or on the
stationary leaf) or directly on the floor.

Bottom track

 

profile 

(fig. 14 ref.

 

)

Allows the bottom leaf profile to adapt to the sliding block
mentioned above.

Brush for bottom track profile 

(fig. 14 ref.

 

)

This completes the on-ground track system.

Leaf attachment profile 

(fig. 17 ref. 

)

Allows the top leaf profile to adapt to the carriage attachments.

Pair of bottom sliding blocks for glass leaf

They enable the glass leaves to slide.

4.

HEAD PROFILE CONFIGURATION

To correctly position the head profile parts, refer to the dimensions of
the following figures:
Fig. 4 right opening, Fig. 5 left opening and Fig. 6 double-leaf.

With the FAAC series 940 SMT systems, two- or  four-leaf sliding doors
can be automatically activated, managed and controlled.
The FAAC series 940 SMT automated systems are supplied fully
assembled, wired and tested in the configuration requested by the
customer on the order form, or supplied as a kit.
An automation head profile (fig.1 ) consists of the following parts:

Head profile 

(fig.1 ref. 

)

The profiles in extruded aluminium, used for the different head profile
models (tab.1) come in two versions:

Profile SM 

(fig.2 and 3 ref.

 

)

This is the support profile which is used when the head profile can be
entirely fitted on a bearing structure. The profile's sliding track is
coated with a special plastic material which, in addition to
protecting the aluminium profile against wear, ensures silent
operation with a very low friction coefficient.

Telescopic   profile 

(fig.2 and 3 ref.

 

)

This is the support profile for the telescopic leaves.

Profile SMA 

(fig.3 ref.

 

)

This consists of a support  profile (SM) and another profile (A)
providing the free-standing characteristic.
The head profile can be secured at the two ends, using the "Side
fixing brackets kit".
The free-standing profile secured at the ends is guaranteed up to a
maximum length of 3,000 mm - for greater lengths, the head profile
must be secured at its intermediate points too, using the
appropriate slots.

Leaf support carriages

 (fig.1 ref.

)

The carriages are provided with two wheels on ball bearings, a
counter  wheel on the lower part, and a screw system for adjusting
leaf height.

Motor/transformer unit

 (fig. 1 ref.

)

The DC motor is supplied with an encoder and a leaf locking system
(accessory).

Control unit 

(fig. 1 ref. 

)

When the  microprocessor control unit  is powered up, it executes an
initialisation process of the door's functional parameters.

Opening mechanical stop

 (fig. 1 ref. 

)

Transmission pulley unit

 (fig. 1 ref. 

)

Drive chain

 (fig. 1 ref. 

)

3.

ACCESSORIES

FAAC has three groups of articles complementing the installation of
the automatic door.

3.1

Supplied accessories for the head profile

These are the articles which, following a request on the order form,
are assembled on the head profile directly by FAAC. These
accessories, which can be, if necessary, installed later on, are as
follows:

Front housing 

(fig.2 ref. 

  and fig. 3 ref. 

)

The front housing is available in natural or anodised aluminium.The
side panels fully enclose the system.

Motor  lock unit

The motor lock  unit guarantees mechanical locking of the door in
any position. A single type of motor lock is used for  either single- or
double-leaf applications.
The motor lock is supplied with an internal release device enabling
emergency opening if necessary; it is also designed for installation of
the external release (paragraph 3.2 key push-buttons T20EF and

940SMT2/SMT4 SERIES AUTOMATIC DOORS

2.

DESCRIPTION AND TECHNICAL SPECIFICATIONS

Summary of Contents for 940SMT

Page 1: ...940SMT 940SMT para la naturaleza 100 papel reciclado ist umweltfreundlich 100 Altpapier pour la nature papier recycl 100 for nature recycled paper 100 carta riciclata 100 per la natura...

Page 2: ...t Mechanical movement risks such as crushing dragging and shearing CE DECLARATION OF CONFORMITY FOR MACHINES DIRECTIVE 89 392 EEC ANNEX II PART B Manufacturer FAAC S p A Address Via Benini 1 40069 Zol...

Page 3: ...FILE HOUSING PROFILE SLIDING PROFILE CLOSING PROFILE FOR STANDARD AUTOMATED SYSTEM CLOSING PROFILE FOR FREE STANDING AUTOMATED SYSTEM CLOSING PROFILE FOR TELESCOPIC AUTOMATED SYSTEM LEAF ATTACHMENT PR...

Page 4: ...pply Protection class Anti crushing activation Operating ambient temperature Use frequency Motor power supply Head profile length Opening speed adjustment load free Closing speed adjustment load free...

Page 5: ...4 ENGLISH ENGLISH 25 21 4 164 5 205 40 5 79 5 71 5 179 5 14 6 10 15 15 50 251 195 Fig 2...

Page 6: ...5 ENGLISH ENGLISH 14 6 10 15 49 6 135 205 71 5 50 301 35 5 71 5 117 76 2 37 7 50 50 15 15 15 25 195 Fig 3...

Page 7: ...utomatically activated managed and controlled TheFAACseries940SMTautomatedsystemsaresuppliedfully assembled wiredandtestedintheconfigurationrequestedbythe customerontheorderform orsuppliedasakit Anaut...

Page 8: ...5245 1227 2400 3700 1020 1050 845 2580 5305 5445 1277 2500 3850 1070 1100 895 2680 5505 5645 1327 2600 4000 1120 1150 945 2780 5705 5845 1377 2700 4150 1170 1200 995 2880 5905 6045 1427 2800 4300 122...

Page 9: ...900 420 450 180 1380 2905 2765 677 1300 2050 470 500 230 1480 3105 2965 727 1400 2200 520 550 280 1580 3305 3165 777 1500 2350 570 600 330 1680 3505 3365 827 1600 2500 620 650 380 1780 3705 3565 877 1...

Page 10: ...1100 4545 4685 527 1900 2950 295 325 1275 1150 4745 4885 552 2000 3100 320 350 1325 1200 4945 5085 577 2100 3250 345 375 1375 1250 5145 5285 602 2200 3400 370 400 1425 1300 5345 5485 627 2300 3550 395...

Page 11: ...10 ENGLISH ENGLISH 36 36 200 12 18 HA 165 LH max 2500 14 6 10 5 INSTALLATION HA LH 15 4 mm 10 Fig 7...

Page 12: ...11 ENGLISH ENGLISH HA LH 15 4 mm 10 Fig 8 14 6 10 LH max 2500 12 18 135 HA 200...

Page 13: ...ee securing points Carry out the remaining securing operations every 20 cm on the vertical slots as shown in figure 8 Free standing profile securing with side brackets The automation head profile with...

Page 14: ...ugs and screws 8 2 Adjustment of the counter roller The carriages are supplied with a counter wheel Adjustment procedurebelow Loosen the two hexagon head screws fig 18 ref and Slide the screw fig 18 r...

Page 15: ...ightenthecarriage sfixingscrews Fig 25 11 INSTALLATION OF HOUSING FIXING BRACKETS Fit a housing fixing bracket at the end of the head profile opposite the motor unit using the supplied screws and plat...

Page 16: ...Fully screw the adjuster on the bracket Pull the knob and rotate it through 90 so that it locks on the bracket Thread the cable fig 33 ref inside part leaving the sheath at its limit stop Fit the cab...

Page 17: ...t it and push it toward the profile until the metal projection fits into the profile seat fig 35 ref Fasten the parachute cables on the housing and on the housing fixing brackets as shown in fig 35 re...

Page 18: ...17 ENGLISH ENGLISH Fig 40 16 INSTALLATION WITH GRIPPERS FOR GLASS LEAVES HA LH 4 5 18 4 21 10mm To install with the glass leaves grippers refer to the dimensions infigure 40...

Page 19: ...from the toroidal transformer from the motor and from all accessories routing the cables inside the pre fittedcablesleeves Set motor direction of rotation according to type of door refer to the instru...

Page 20: ...see table LED ERROR STATUS MEANING OFF normal operating status ON Alarms n 18 20 22 24 execute SETUP SLOW FLASHING current alarm signalling FAST FLASHING setup reset in progress or during setup with...

Page 21: ...ISABLED DEFAULT no photocell 1 pair of photocells 2 pairs of photocells PSW 2 PSW 1 FAILSAFE VACC 1 2 3 4 5 6 7 8 9 10 11 12 13 14 RX1 TX1 C J5 PSW 2 PSW 1 FAILSAFE VACC 1 2 3 4 5 6 7 8 9 10 11 12 13...

Page 22: ...ERMINAL BOARD J6 TERMINAL BOARD 1 24V 24V power supply for accessories The total maximum load of the accessories connected to the VACC and 24V inputs must not exceed 700mA 2 OUT 3 default door not clo...

Page 23: ...Keeper Display as an alternative one photocell only can be set connecting it to the PSW1 input as usual thus disabling the PSW2 input and avoiding the jumper see the SD Keeper programming instruction...

Page 24: ...nt partial opening and re closing after pause time no effect no effect no effect no effect restarts pause time count total opening and re closing after pause time restarts pause time count partial ope...

Page 25: ...AGNOSTICS DIAGNOSTICS DIAGNOSTICS DIAGNOSTICS SD Keeper also without display has a diagnostic function which in case of an alarm interrupts normal display of the function every 2 seconds in order to s...

Page 26: ...range of pause time 0 to 90 sec DOOR OPEN DOOR OPEN DOOR OPEN DOOR OPEN DOOR OPEN The door opens and stays open NIGHT NIGHT NIGHT NIGHT NIGHT The door closes and the lock if present is activated The i...

Page 27: ...OK key An asterisk on the display indicates the currently active setting To exit programming select the exit function at each level Otherwise after about 2 minutes the display automatically returns to...

Page 28: ...OK OK OK 4 1 OK OK OK 4 2 OK OK 4 3 4 OK OK OK OK OK OK 5 OK OK 5 1 5 2 OK OK OK BATTERY BATTERY KIT ON OFF NO STANDARD STANDARD BAT OPERATION OPENING NO STANDARD STANDARD CLOSING NIGHT BATT LAST OPER...

Page 29: ...1 OK OK OK OK OK OK OK 1 1 1 2 1 3 1 4 2 3 4 OK OK OK OK OK OK PASSWORD 0000 ADVANCED MENU PASSWORD 0000 PASSWORD 0000 PASSWORD 0000 OPERATION PARAMETERS CLOSING SPEED OPENING SPEED DECEL WIDTH DECEL...

Page 30: ...OK OK PASSWORD 0000 ADVANCED MENU PASSWORD 0000 PASSWORD 0000 PASSWORD 0000 incorrect code correct code OPERATION PARAMETERS IN OUT SETUP VARIOUS EXIT CHANGE PASSWORD EMERG 1 OPEN STOP CLOSE SPEED NO...

Page 31: ...K OK OK OK OK OK OK 3 3 PASSWORD 0000 ADVANCED MENU PASSWORD 0000 PASSWORD 0000 PASSWORD 0000 incorrect code correct code OPERATION PARAMETERS IN OUT SETUP VARIOUS EXIT CHANGE PASSWORD STAND SETUP STA...

Page 32: ...AND 2 FUN 0 00 00 TIME BAND 5 FUN 0 00 00 TIME BAND 4 FUN 0 00 00 TIME BAND 3 FUN 0 00 00 TIME BAND 1 FUN 0 00 00 TIME BAND 2 FUN 0 00 00 TIME BAND 5 FUN 0 00 00 TIME BAND 4 FUN 0 00 00 TIME BAND 3 FU...

Page 33: ...at the point where the obstacle had been detected and continues at the slower speed until completed Opening No Standard Opening No Standard Opening No Standard Opening No Standard Opening No Standard...

Page 34: ...value 0 cm Adjusting range from 0 to 120 cm Closing Closing Closing Closing Closing Sets anticipated time value on the standard deceleration point at the closing stop position Standard value 0 cm Adju...

Page 35: ...a black out Off Off Off Off Off Elastic kit not installed On On On On On Elastic kit installed Standard Standard Standard Standard Standard When power is restored after a blackout the door remains set...

Page 36: ...ecute the Setup activate the elastic kit with SD Keeper Display install the accessory mechanically After installation the leaves will open when mains power fails when mains power is restored the elast...

Page 37: ...charge to perform at least one emergency movement after which the 940SDM control board goes into NIGHT ENERGY SAVING status ENERGY SAVING other than Night operating function VAC is switched OFF SD Ke...

Page 38: ...night pause time elapses The operation is identical if the person comes from the opposite direction INTERLOCK WITHOUT INTERNAL SENSORS INTERLOCK WITHOUT INTERNAL SENSORS INTERLOCK WITHOUT INTERNAL SEN...

Page 39: ...RY function was selected for theEMERG2input whenthecontactisrestored RESET is necessary to cancel the signal 3 4 7 EMERG 1 ON Emergency input 1 active This signal is shown whenever the EMERG1 emergenc...

Page 40: ...execute a new SETUP 2 4 22 The SETUP procedure cannot be completed because excessive friction or excessive leaf weight was detected When this signal is generated the ERROR LED on the 940SDM control bo...

Page 41: ...alarm in progress connect the SD Keeper to find the alarm and take the appropriate action see the diagnosticsguide G door locked and ERROR LED ON SETUPmustbeexecuted alarm in progress connect the SD K...