DESCRIPTION OF TERMINALS
DESCRIPTION OF TERMINALS
DESCRIPTION OF TERMINALS
DESCRIPTION OF TERMINALS
DESCRIPTION OF TERMINALS
TERMINAL BOARD J5
TERMINAL BOARD J5
TERMINAL BOARD J5
TERMINAL BOARD J5
TERMINAL BOARD J5
1
RESET
(NO contact)
Contact closure executes the Reset procedure.
Reset is the function for restoring normal operating
conditions after some types of alarm.
2-5-8-11
- (COM)
Negative for powering accessories (+24V and +Vacc)
and common for contacts
3
EMERG2
(NO default contact)
Emergency command:
in the standard setting, activation causes the door to
open (the door stays open for as long as the command
is activated).
By using SD-Display, you can program the
operation of this input differently (see programming
instructions).
4
EMERG1
(NO default contact)
Emergency command:
in the standard setting, activation causes the door to
stop (the door stays in stop status for as long as the
command is activated).
By using SD-Display, you can program the
operation of this input differently (see programming
instructions).
6
-FAILSAFE
Negative for powering photocell projectors when the
FAILSAFE function is activated (programmable from SD-
Display).
7-14
+V
ACC
+24V power supply for accessories.
The total maximum load of the accessories connected
to the “+V
ACC
” and “”+24V” inputs, must not exceed
700mA.
Â
While operating on the battery in the absence of
mains power, when the battery charge drops to a
critical level, Vacc is interrupted for energy saving
purposes.
9
PSW2
(NC default contact)
Input of 2nd safety photocell
By using SD-Display , you can :
- program the NO contact,
- cut out this input if there are no photocells or if there is
only one photocell (which must therefore be connected
to the PSW1 input).
For the effects the tripped photocell has on this input,
see PSW1.
10
PSW1
(NC default contact)
Input of 1st safety photocell
By using SD-Display , you can :
- program the NO contact,
- cut out this input if there are no photocells.
Following intervention by the photocell connected to
this input, the door behaves as follows:
OPENING:
no effect
PAUSE:
pause time re-counted
CLOSING:
reverses immediately
12
I-DET
(NO default contact)
Internal sensor input.
By using SD-Display , you can program the NC
contact.
13
E-DET
(NO default contact)
External sensor input.
By using SD-Display , you can program the NC
contact.
J6 TERMINAL BOARD
J6 TERMINAL BOARD
J6 TERMINAL BOARD
J6 TERMINAL BOARD
J6 TERMINAL BOARD
1
+24V
+24V power supply for accessories.
The total maximum load of the accessories connected
to the “+V
ACC
” and “”+24V” inputs, must not exceed
700mA.
2
OUT 3 (default “door not close”)
Open-collector (negative) output (100mA).
In the standard setting, this output is active for as long as
the door is not closed.
By using SD-Display , you can program the
operation of this output differently (see programming
instructions).
3-5-9
- (COM)
Negative for powering accessories (+24V and +Vacc)
and common for contacts.
4
OUT 2 (default : “night courtesy light”)
Open-collector (negative) output (100mA).
In the standard setting, this output is activated for 60 sec.
when the door is commanded to open in NIGHT mode.
By using SD-Display, you can program the
operation of this output differently (see programming
instructions).
6
MONODIR
(NO contact)
If the SD-Keeper is not installed, closing this contact
activates the “ONE WAY” function.
7
NIGHT
(NO contact)
If the SD-Keeper is not installed, closing this contact
activates the “NIGHT” function.
8
OPENED
(NO contact)
If the SD-Keeper is not installed, closing this contact
activates the “DOOR OPEN” function.
10
OUT 1
(“gong” default)
Open-collector (negative) output (100mA).
In the standard setting, this input is active, while the
photocells are covered, for 1 sec. at 0.5 sec. intervals
until disengaged.
By using SD-Display, you can program the
operation of this output differently (see programming
instructions).
11
KEY
(NO default contact)
Key command:
activation causes the door to open and then re-close
after night pause time elapses.
By using SD-Display , you can program the NC
contact.
12-13
SD-KEEPER
SD-Keeper connection terminals (cable: 2x0.5mm
2
max
50m).
Â
Observe indicated polarity.
TERMINAL BOARD J7
TERMINAL BOARD J7
TERMINAL BOARD J7
TERMINAL BOARD J7
TERMINAL BOARD J7
NOT AUS
(NC contact)
Contact for the emergency push-button (NC) which cuts
power to the motor.
Â
If not used, jumper the terminals with a 0.5mm
2
cable.
MOTOR ROT
MOTOR ROT
MOTOR ROT
MOTOR ROT
MOTOR ROTA
AA
AATION DIRECTION
TION DIRECTION
TION DIRECTION
TION DIRECTION
TION DIRECTION
Set dip-switch n°1 as follows:
DOOR MODEL
DIP-SWITCH N°1
2 LEAVES
OFF
1 LEFT OPENING LEAF
ON
1 RIGHT OPENING LEAF
OFF
Â
The closing direction is established by watching the
automated system head profile from the front and:
- in the case of a double leaf, the LEFT leaf connected
to the bottom section of the belt.
- in the case of a right-opening single leaf, the leaf
always connected to the top section of the belt.
- in the case of a left-opening single leaf, the leaf
always connected to the bottom section of the belt.