background image

13

1,5

Fig. 18

Fig. 19

Fig. 17

Fig. 16

Fig. 15

Fig. 14

4.4.2.  STEEL RACK TO BE BOLTED (Fig. 16)

1) Manually place the leaf in closed position.
2) Rest the first section of the rack level

on the pinion gear and insert the
spacer between the rack and the
gate, locating it in the upper part
of the slot.

3) Mark the drilling point on the gate.

Drill Ø 6.5 mm. and tap with a Ø 8
mm. taps. Tighten the bolt.

4) Move the gate by hand, checking

whether the rack rests on the
pinion and repeat operations at
point 3.

5) Position another rack element next to the previous one, using

a section of rack as in Fig. 15.

6) Move the gate by hand and execute the securing operations

as done for the first element, carrying on until you have
covered the entire gate.

Notes on the rack

As the gate moves, make sure that no rack elements lose
contact with the pinion.

Do not, repeat do not, weld the rack elements either to the
spacer or to each other.

After installing the rack, to ensure correct meshing with the
pinion gear, we advise you to lower
the position of the gearmotor by
approximately 1.5 mm (Fig.17).

Manually check that the gate
reaches the mechanical limit stops
correctly, and that there is no
friction during travel.

Do not apply grease or other
lubricants between rack and
pinion.

4.5.

INSTALLING THE CHAIN PINIONS

In the chain application versions, a Z16 or Z20 chain pinion has
to be assembled.
Proceed as follows:
- Fit the elastic pin on the shaft, using a hammer (Fig. 18)
- Install the chain pinion on the shaft, making the pinion seats
coincide with the elastic pin, and tighten the screws with the
washers (Fig. 18).
-Assemble the chain as shown in Fig. 19.

5.

CONNECTIONS FOR THE CONTROL UNIT

The 844R 3Ph operator can be installed using an 844 T remote
control unit. The 844 INTERFACE board is installed on board the
operator (fig. 20).
Make the connections, following the lay-outs in the instructions
for the 844 T electronic control unit.

interface
board

Summary of Contents for 844R 3P

Page 1: ...ata 100 per la natura for nature recycled paper 100 ist umweltfreundlich 100 Altpapier para la naturaleza 100 papel reciclado papier recycl 100 pour la nature voor de natuur 100 kringlooppapier 844R 3...

Page 2: ...observe Good Technique in the constructionoftheclosingelementstobemotorised orforanydeformation thatmayoccurduringuse 10 TheinstallationmustconformtoStandardsEN12453andEN12445 Fornon EUcountries toobt...

Page 3: ...h p 3 0 0 4 Table1 TECHNICALSPECIFICATIONSOFGEARMOTOR These instructions apply to the following model 844R 3Ph The FAAC mod 844R 3Ph automation for sliding gates is an electromechanical operator power...

Page 4: ...r electrical cables in the plinth excavation area If the gearmotor is exposed to passing vehicles if possible fit adequate guards to protect against accidental impact Check if an efficient earth plate...

Page 5: ...dation plate tightening the nuts as shown in Fig 12 4 4 INSTALLING THE RACK 4 4 1 STEEL RACK TO BE WELDED Fig 13 1 Fit the three threaded pawls on the rack element locating them in the upper part of t...

Page 6: ...ack elements either to the spacer or to each other After installing the rack to ensure correct meshing with the pinion gear we advise you to lower the position of the gearmotor by approximately 1 5 mm...

Page 7: ...a transiting plate fitted on the top of the rack it commands gate motion to stop Procedure for correct positioning of the two supplied plates 1 Assemble the limit sensor centring the plate with respe...

Page 8: ...ON If the gate has to be moved manually due to a power cut or fault of the automatic system use the release device as follows 1 Open the protective door and fit the supplied key in the lock Fig 26 2 T...

Page 9: ...s 12 MAINTENANCE Run a functional check of the system at least every 6 months with special attention to the efficiency of the safety devices Including the thrust force of the operator and release devi...

Page 10: ...uipment receives an opening command by remote control or from another suitable device it activates the motor until the opening position is reached If automatic operating mode was set the gate closes a...

Page 11: ...chappen van de apparaat gehandhaafd blijven zonder zich daardoor te verplichten deze publicatie bij te werken Timbro del Rivenditore Distributor s Stamp Timbre de l Agent Fachh ndlerstempel Sello del...

Reviews: