16
Fig. 29
Fig. 28
10. ASSEMBLY OF THE CN 60E CONTROL
UNIT (OPTIONAL)
The operator is designed to house - with the aid of a DIN bar -
the control unit of the CN 60E conductive safety edge. Cut the
DIN bar to measure and secure it to the operator with two screws
in the two appropriate holes, and hook on the CN 60E control
unit (Fig. 28).
For connection and operation, consult the specific instructions.
11. SPECIAL APPLICATIONS
There are no special applications.
12.
MAINTENANCE
Run a functional check of the system at least every 6 months,
with special attention to the efficiency of the safety devices
(Including the thrust force of the operator) and release devices.
13. REPAIRS
For repairs, contact FAAC authorised Repair Centres.
Periodically check quantity of oil inside the operator.
An annual check is sufficient for low to medium use frequency;
for heavier duty, check every 6 months.
To access the tank, temporarily remove the oil filling plug (Fig.29).
Oil visual check: oil must touch the copper windings of the
electric motor.
To top up, pour in oil up to the level.
Use only FAAC XD 220 oil.
12.1. TOPPING UP OIL