Technical Data
The 750 Operator
750 Standard
750 Long Leaf
750 Extra Long Leaf
Ambient temperature, deg F (deg C)
-13 to 158 (-25 to 70)
Maximum duty cycle
30 Cycles/ Hour
Thermal cut out, deg F (deg C)
212 (100)
Power voltage required, VAC*
115 ±10% or 230, +6 or -10%, 60 Hz
230, +6 or -10%, 60 Hz
Absorbed power, W
220
Motor speed, rpm
1400
960
Type of oil
Lubrication Engineers – MONOLEC 6105
Hydraulic Power Unit
:
Height
×
width
×
depth, in. (cm)
13
3
/
4
×
8
3
/
16
×
5
1
/
8
(35
×
20.8
×
13)
Weight, lb (kg)
20 (9)
Oil quantity, qt (l)
1 (0.9)
Hydraulic locking:
CBC: Closed
CBAC: Opened
and
closed
Not available
Not available
Gate weight, lb (kg)
1760 (800)
Maximum gate length, ft (m)
7 (2.1)
10 (3)
13 (4)
Hydraulic Drive Unit
:
Height (not including shaft)
×
length
×
width, in. (cm)
4
7
/
8
×
15
3
/
4
×
7
7
/
8
(12.4
×
40
×
20)
Weight
100-deg swing, lb (kg)
180-deg swing, lb (kg)
18 (8)
20 (9)
Oil quantity, qt (l)
0.9 (1)
Maximum angle of rotation
100-deg swing, deg
180-deg swing, deg
118
200
90-deg opening time, sec
12
17
Nominal torque, ft-lb (Nm)
338 (460)
* Your standard 220 VAC power source meets the specification for 230 VAC, +6 or -10%.
The Control Panel
The 750 Operator must be installed with a 450 MPS
control panel to be a U.L. recognized installation. The
450 MPS can be used to control a single 400 operator or
a dual (biparting) system. Both the control panel and
the operator must use the same power supply voltage.
The 450 MPS
To determine the voltage requirement of your 450 MPS
control panel, refer to the label on the transformer of the
control panel:
Label reads: 450MPSUS = 220 VAC
450MPSUS115 = 115 VAC
Operating logics available: E, EP, A, S, B, and C