background image

1

Swing Gate Opener

User Manual

SW200DC

Website: www.gatexpertstore.com

E-mail: [email protected]

Summary of Contents for SW200DC

Page 1: ...1 Swing Gate Opener User Manual SW200DC Website www gatexpertstore com E mail sales gatexpertstore com...

Page 2: ...eplace for free 4 The malfunction and damages caused by incorrect use or man fault is not covered by this warranty CONTACT US E mail sales gatexpertstore com Please fill in the order information in th...

Page 3: ...meet the specific requirements The disposal of packaging material must be complying with the local regulation Please do not change any parts except for those defined under this manual Any undefined ch...

Page 4: ...rd No Picture Name Quantity 1 Main machine 2 2 Control box 1 3 Manual release key 2 4 Remote control 2 5 Wall bracket 4 6 Front mounting bracket 2 7 Connecting bracket 2 8 Screw M8X25 4 9 Mounting scr...

Page 5: ...rs and wall Please prepare the these installation accessories according to actual site situation 3 Technical Parameters Model SW200DC Power supply 220V 50Hz 110V 60Hz Motor power 30W Gate moving speed...

Page 6: ...orter than 2m The drive mode adopts planetary transmission to combine with the screw rod transmission This gate opener must be installed inside the enclosure or yard for protection 5 Tools Needed for...

Page 7: ...y 2 1 5mm 15m 3 Cable of infrared sensor 2 0 5mm 10m 4 Cable of alarm lamp 2 0 5mm 10m 5 Cable of electric lock 2 0 5mm 10m 6 Extension cable of storage battery 2 1 5mm 10m 7 Cable of solar power 2 1...

Page 8: ...has interference after the gate completely open please install a gate safety stopper prepare by user to prevent injury to person or damage to property A B 100mm 120 mm 140 mm 160 mm 180 mm 200 mm 100...

Page 9: ...111 5 108 5 106 5 105 103 100 5 140mm 118 5 115 112 5 106 96 5 160mm 121 110 101 5 93 5 180mm 106 98 5 92 200mm 96 5 90 5 Note If the interval between the gate and the wall is too small or it has int...

Page 10: ...d to consider the distance between the two swings c The recommended mounting height of the 2 main machines is around 300 800mm above the ground and make sure there are reliable fixed points for mounti...

Page 11: ...ll brackets please refer to Figure 5 Figure 5 B The connecting bracket and the wall bracket can be connected according to different conditions please refer to figure 6 Figure 6 C Before the installati...

Page 12: ...ackets by screw and nut as shown in Figure 8 M8 45 M8 Figure 8 E As shown in figure 9 below connect wall bracket with wall according to marked position Then connect main machine with wall bracket by s...

Page 13: ...Instructions for SW200DC www gatexpertstore com 11 M8 Figure 9 8 3 Dimension of Control Box 250mm 170mm 78 75mm Figure 10 Front mounting bracket Self locking nut Mouting screw short...

Page 14: ...sition as shown in figure 2 Before installing the main machine please make sure the main machine and components are in good mechanical performance and the gate can be manually operated flexibly One co...

Page 15: ...Instructions for SW200DC www gatexpertstore com 13 9 Wiring and Debugging 9 1 Wiring Instructions Figure 11...

Page 16: ...Lock Output 10 BLK Alarm Lamp Output Note pay attention to the negative and positive 11 24V 24V Output Positive 12 12V 12V Output Positive No output under dormant state 13 EM1 Motor1 Hall Sensor Powe...

Page 17: ...Instructions for SW200DC www gatexpertstore com 15 Photo Seneor Wiring Instructions Figure 13 WIFI Module Wiring Instructions Figure 14...

Page 18: ...SU After this step the gate will firstly run towards the closing direction and stop and then the gate will automatically open When the two swing gates are fully open the gates will automatically clos...

Page 19: ...lockwise to slow down The trimmer can be adjusted to change the opening and closing travel time This adjustment must be finished before travel setting Figure 15 9 6 Learning Remote Control Delete Remo...

Page 20: ...tings 9 7 1 Base Menu Press PROG to enter into base menu Digital screen shows NE select other functions of this menu by and buttons Press SET to confirm or to enter into sub menu To exit menu press PR...

Page 21: ...To switch single gate mode dual gates mode Single gate mode Open gate time interval 3 seconds default 15 seconds default Automati c closing time Remote control mode Dual gates single channel mode Four...

Page 22: ...c closing function will be canceled Community mode with automatic closing function When the gate opens any gate command will not be responded until it closes automatically If user sends gate command d...

Page 23: ...keys o p s Automatic closing with Single Gate Dual Gates Switch Dual gates mode default Single gate mode Dual gates mode Open Gate Time Interval 00 10 Open gate time interval is 0 10 seconds default...

Page 24: ...rol board will automatically enter the low consumption mode after 1 minute Low consumption mode off Low consumption mode on 9 7 3 Advanced Menu Instruction Long press PROG 2 seconds to enter into adva...

Page 25: ...off Electric lock normally on Alarm lamp Electric lock Alarm lamp normally flash Gate opener secection Stop block Hall sensor Limit switch mode Alarm lamp normally on SW400DC SW300DC Electric lock nor...

Page 26: ...r SW200DC www gatexpertstore com 24 SW200DC Direction of the door Gate Opens Inwards Gate Opens Outwards Buzzer The buzzer is off The buzzer is on Factory initialization uninitialize Complete initiali...

Page 27: ...under the resistance limit the farther the deceleration distance of the door And in the Hall limit the shorter the time the shorter the door travel Photo Sensor N C photo sensor normally is on Defaul...

Page 28: ...ult Alarm lamp normally flashes 24V power supply Alarm lamp normally is on 24V power supply Limit Switch Mode Stop block Default Hall sensor Stop block Gate Opener Secection SW400DC SW300DC Default SW...

Page 29: ...erve the right to change the instruction without prior notice 10 2 Error Message Errors that may occur when the door is operating properly Wrong Indication Cause of Error Solution Door 1 Obstructed in...

Page 30: ...ensitivity appropriately 3 Increase deceleration distance appropriately Door 2 is closing with difficulty 1 Check whether there are obstacles when door 2 is closed 2 Adjust resistance sensitivity appr...

Page 31: ...ng position can be mutually aligned 3 Remove the obstacle 4 Reduce the sensitivity of obstacle Remote control doesn t work 1 Battery level of the remote control is low 2 Remote control learning is not...