21
COM
NC
NO
A: 1 = COM
2 = NC
3 = NO
B: 4 = COM
5 = NO
6 = RESET
7 = +
8 = -
9 & 10 = LOOP
Free Exit/Safety
Loop Detector
NO
CO
M
N
C
3
2
1
White
wire
leads
LOCK
1
2 3
4
5
6
7
8
9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
Figure 17. Wiring diagram showing loop detector
FAAC International, Inc., strongly recommends you
install reversing devices. If you choose not to install
such devices, then you must install the necessary
circuit(s) for the control panel to work.
•
If you do not install an opening reversing
device, install a circuit between 11 and 21 on
terminal block J3.
•
If you do not install a closing reversing device,
install a circuit between 13 and 21 on terminal
block J3.
In addition, terminal block J3 requires a fail-safe
connection for the photocells. Connect the photocells to
terminals 20 and 21.
Activating Devices and Radio Receiver
: The acti-
vating devices and radio receiver for your gate must
have normally open (N.O.) contacts. If you have only
one gate leaf, connect such devices to terminals 16 and
17. If your gate has two leaves, connect the devices to
terminals 18 and 19.
In addition, terminal block J3 requires a fail-safe
connection for the transmitter of your photocells.
Connect the transmitter to terminals 20 and 21 in the
FSWTX grouping.
See Figure 18 for how to wire a three-wire receiver and
Figure 19 for how to wire a four-wire receiver.
LOCK
FSWTX W.LIGHT
30 Vcc
FSW
STOP
9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
+
OP
CL
—
NC
B
A
—
—
—
—
—
+
+
—
NO
COM
24
VDC
3-Wire
Receiver
Figure 18. Connect a three-wire receiver