746 E R
8
732099 - Rev.D
Tr
ansla
tion of the original instruc
tions
ENGLISH
3.4
EMERGENCY USE
3. 746 E R
-
Uses other than the intended use are prohibited.
-
It is prohibited to install the automation system outside of the
limits specified in the Technical Data and Installation Require-
ments sections.
-
It is forbidden to use 746 E R in a constructional configuration
other than the one provided by the manufacturer.
-
No component part of the product may be modified.
-
It is prohibited to install the automation system on escape routes.
-
It is prohibited to install the automation system to create fire
doors.
-
It is prohibited to install the automation system in environments
in which there is a risk of explosion and/or fire: the presence of
flammable gases or fumes is a serious safety hazard.
-
It is prohibited to power the system with energy sources other
than those specified.
-
It is prohibited to integrate commercial systems and/or
equipment other than those specified, or use them for purposes
not intended and authorised by their respective manufacturers.
-
Do not allow water jets of any type or size to come into direct
contact with the gear motor.
-
Do not expose the gear motor to corrosive chemicals or atmo-
spheric agents.
-
It is prohibited to use and/or install accessories which have not
been specifically approved by FAAC S.p.A.
-
It is prohibited to use the automation system before performing
commissioning.
-
It is prohibited to use the automation system in the presence of
faults which could compromise safety.
-
It is prohibited to use the automation system with the fixed and/
or mobile guards removed or altered.
-
Do not use the automation system unless the area of operation
is free of persons, animals or objects.
-
Do not enter/remain in the area of operation of the automation
system while it is moving.
-
Do not try to prevent the movement of the automation system.
-
Do not climb on, hold onto or let yourself be pulled by the
leaf. Do not climb onto the gear motor.
-
Do not allow children to approach or play in the area of operation
of the automation system.
-
Do not allow the control devices to be used by anyone who is
not specifically authorised and trained to do so.
-
Do not allow the control devices to be used by children or persons
with mental and physical deficiencies unless they are supervised
by an adult who is responsible for their safety.
!
During manual operation, gently guide the leaf the whole way, do not push
it and let it slide freely.
3.3 UNAUTHORISED USE
3.1
INTENDED USE
FAAC746 E R series gearmotors are designed to operate horizontal
sliding gates for residential buildings / apartment complexes.
Only one gearmotor must be installed for each leaf. The system
requires a special foundation plate, supplied separately, which is
embedded in a plinth. The gate must be moved via a rack.
The 746 E R is intended for installation on gates in areas that are ac-
cessible by people, the main purpose of which is to provide access
for goods, vehicles and people.
To move the gate manually, follow the instructions in section
§
Manual
operation.
!
Any other use that is not expressly specified in these instructions is prohibited
and could affect the integrity of the product and/or represent a source of
danger.
3.2 LIMITATIONS OF USE
The maximum force required to move the leaf by hand over its entire
length of travel must be 225 N for residential areas and 260 N for
industrial or commercial areas.
The maximum force required to start the movement must be less
than the maximum torque at initial thrust of the operator indicated
in the technical data.
The leaf must fall within the dimensional and weight limits indicated
in the technical data.
The presence of weather conditions such as snow, ice and strong wind,
even occasional, could affect the correct operation of the automation,
the integrity of the components and be a potential source of danger
(see § Emergency use).
746 E R is not designed to be a security (break-in protection) system.
If there is a pedestrian access gate integrated in the leaf of the gate,
the motorised movement must be disabled when the pedestrian gate
is not in a safe position.
The installation must be visible during the day and at night. If it is
not, appropriate solutions must be provided to make the fixed and
moving parts visible .
Implementing the automation requires the installation of the neces-
sary safety devices, identified by the installer through an appropriate
risk assessment of the installation site.
In emergencies or if there is a fault, turn off the power supply to the
automation . If the leaf can be moved safely by hand, use the MANUAL
OPERATION mode; otherwise place the automation out of service until
it has been reset/repaired.
In the case of a breakdown, the automation must be reset/repaired
exclusively by the installer/maintenance technician.