Board technical data
780D [230 V~]
780D [115 V~]
Power supply voltage
220-240 V~ 50/60 Hz
115 V~ 50/60 Hz
Max power
10 W
10 W
Max. motor power
1000 W
1200 W
Max accessories load 24 V
"
500 mA
500 mA
Ambient operating temperature
-20°C to +55°C
-20°C to +55°C
Flashing light
230 V~ - 60 W
115 V~ - 60 W
7.3 CONNECTIONS
F
Carry out the work with the power supply disconnected.
!
Do not exceed the maximum load of the outputs.
MOTOR
The connection to terminal board
J6
is carried out at the factory (
34
).
!
DO NOT modify the factory connection. If the direction of rotation of the
motor has to be reversed, modify function
d l
in basic programming.
TERMINAL BOARD J6
15
COM
Common (grey or blue)
16
17
MOT 1
MOT 2
Phase (black)
Phase (brown)
FLASHING LIGHT
Connect the flashing light to terminal board
J6
(
34
).
MAGNETIC ENCODER
The magnetic encoder sensor detects the rotation of the magnet on
the shaft (
34
).
The sensor is integrated in the board and does not need to be con-
nected.
START-UP CAPACITOR
Connected at the factory: rapid connector
J5
(
35
).
TRANSFORMER
The transformer is factory installed (connectors
J3
-
J4
) (
35
).
MAGNETIC LIMIT STOP SENSOR
Connected at the factory: rapid connector
J9
(
35
).
transformer
magnet