17
328
187
2804 / 3403 / 3998
415
These instructions apply to model FAAC 531EM.
The 531EM automated systems make it possible to automate
balanced sectional doors of single garages for residential use.
They consist of an electromechanical operator, electronic
control equipment and courtesy light built into a single unit
which, fitted to the ceiling, allows door opening by means of a
chain or belt transmission.
The non-reversing system guarantees mechanical door locking
when the motor is not operating, therefore no lock is necessary;
a manual release on the inside and one on the outside (optio-
nal) allow the door to be moved manually in case of a power
failure or malfunction.
The operator is supplied with an electronic device that detects
the presence of an obstacle that would hinder door movement,
and that prevents crushing or lifting.
These instructions refer to the operator with chain drive, but the
same procedures, adjustments and application limits also apply
to the operator with belt drive.
The 531EM automatic systems are designed and built for indoor
use and for controlling vehicle entry. Any other use is improper.
1. TECHNICAL SPECIFICATIONS
MODEL
531EM
Power supply (Vac +6 -10% 50Hz)
230
Electric motor (Vdc)
24
Maximum absorbed power (W)
220
Thrust force (N)
600
Type of use
Continuous
Minimum distance from ceiling (mm)
35
Courtesy light (Vac-W)
230 - 25 max
Courtesy light timer (sec)
120
Standard speed of carriage load free (m/min)
6,6
Lower speed of carriage load free (m/min)
3,8
Deceleration speed (m/min)
1,3
Noise at standard speed (dB(A))
45
Deceleration travel length
Varies according to setup
Intrinsic safety device
Category 2
Sectional door max. width (mm)
5000
Door max. height
see useful travel
Useful sliding guide travel (mm)
1900 - 2500 - 3100
Protection rating
for indoor use only
Ambient temperature (°C)
-20 / +55
AUTOMATIC SYSTEM 531EM
2. DIMENSIONS
Fig. 1
햲
Cable 2 x 0.5 (TX photocell)
햳
Cable 4 x 0.5 (RX photocell)
햴
Cable 3x0.5 (Radio receiver)
햵
Power tubing (230V)
햶
Low voltage tubing
햷
Cable 2 x 1.5 + earth (power supply)
Fig. 2
Dimensions in mm
3. ANCILLARY ELECTRICAL EQUIPMENT
Prepare the electrical system in compliance with the instructions
in the chapter entitled "Warnings for the installer".
When you have finished installing, check if any external pipes
or cables can come into contact with moving parts.
Install the fixed control points at a minimum height of 150 cm,
clear of the door movement area, but in a position enabling
visual control of that area.