5. PRELIMINARY CHECKS
The door structure must be suitable for automation. In particular,
check that the door dimensions conform to those given in the
technical specifications and that the door is strong enough.
Check if the door conforms to standards EN12604 and EN12605.
As it moves, the door must not encroach public areas dedicated
to pedestrian or vehicle transit.
Check the efficiency of the door bearings and joints.
Make sure that the door is friction free. If necessary clean and
lubricate the guides with silicone based products, but do not
use grease, and, in any event, follow the constructor's
instructions.
Check correct balance and if the opening mechanical stops
have been installed.
4. DESCRIPTION
Remove the door’s mechanical closing devices so that the
door is closed by the automatic system.
Check if there is an efficient earth plate for electrical
connection of the operator.
Make sure there is a clearance of at least 35 mm between the
ceiling and the highest sliding point of the door (fig. 4).
Check if the upper guide roller of the sectional door is in the
horizontal part of the guide while the door is closed (fig. 5).
Fig. 5
Fig. 4
Fig. 3
햲
Ceiling fixture
햳
Plastic housing
햴
Courtesy light
햵
Electronic equipment
햶
Motor
햷
Operator support
햸
Rear connection
햹
Operator fixing bracket
햺
Sliding guide
햻
Drive carriage
햽
Release knob
햾
Door connection bracket
햿
Transmission unit
헀
Front connection and chain adjuster
헁
Front connection bracket