background image

Page 16 

November, 2003 
455 D Control Panel Installation Instructions 

To the original purchaser only:

 FAAC International, 

Inc., warrants, for twenty-four (24) months from the 

date of invoice, the gate operator systems and other 

related systems and equipment manufactured by FAAC 

S.p.A. and distributed by FAAC International, Inc., to be 

free from defects in material and workmanship under 

normal use and service for which it was intended 

provided

 it has been properly installed and operated. 

FAAC International, Inc.'s obligations under this 

warranty shall be limited to the repair or exchange of 

any part of parts manufactured by FAAC S.p.A. and 

distributed by FAAC International, Inc. Defective 

products must be returned to FAAC International, Inc., 

freight prepaid by purchaser, within the warranty 

period. Items returned will be repaired or replaced, at 

FAAC International, Inc.'s option, upon an examination 

of the product by FAAC International, Inc., which 

discloses, to the satisfaction of FAAC International, Inc., 

that the item is defective. FAAC International, Inc. will 

return the warranted item freight prepaid. The products 

manufactured by FAAC S.p.A. and distributed by FAAC 

International, Inc., are not warranted to meet the 

specific requirements, if any, of safety codes of any 

particular state, municipality, or other jurisdiction, and 

neither FAAC S.p.A. or FAAC International, Inc., assume 

any risk or liability whatsoever resulting from the use 

thereof, whether used singly or in combination with 

other machines or apparatus. 

Any products and parts not manufactured by FAAC 

S.p.A. and distributed by FAAC International, Inc., will 

carry only the warranty, if any, of the manufacturer. This 

warranty shall not apply to any products or parts thereof 

which have been repaired or altered, without FAAC 

International, Inc.'s written consent, outside of FAAC 

International, Inc.'s workshop, or altered in any way so 

as, in the judgment of FAAC International, Inc., to affect 

adversely the stability or reliability of the product(s) or 

has been subject to misuse, negligence, or accident, or 

has not been operated in accordance with FAAC 

International, Inc.'s or FAAC S.p.A.'s instructions or has 

been operated under conditions more severe than, or 

otherwise exceeding, those set forth in the 

specifications for such product(s). Neither FAAC S.p.A. 

or FAAC International, Inc., shall be liable for any loss or 

damage whatsoever resulting, directly or indirectly, 

from the use or loss of use of the product(s). Without 

limiting the foregoing, this exclusion from liability 

embraces a purchaser's expenses for downtime or for 

making up downtime, damages for which the purchaser 

may be liable to other persons, damages to property, 

and injury to or death of any persons. Neither FAAC 

S.p.A. or FAAC International, Inc., assumes nor 

authorizes any person to assume for them any other 

liability in connection with the sale or use of the 

products of FAAC S.p.A. or FAAC International, Inc. The 

warranty hereinabove set forth shall not be deemed to 

cover maintenance parts, including, but not limited to, 

hydraulic oil, filters, or the like. No agreement to replace 

or repair shall constitute an admission by FAAC S.p.A. or 

FAAC International, Inc., of any legal responsibility to 

effect such replacement, to make such repair, or 

otherwise. This limited warranty extends only to 

wholesale customers who buy directly through FAAC 

International, Inc.'s normal distribution channels. FAAC 

International, Inc., does not warrant its products to end 

consumers. Consumers must inquire from their selling 

dealer as to the nature and extent of that dealer's 

warranty, if any. 

This warranty is expressly in lieu of all other 

warranties expressed or implied including the war-

ranties of merchantability and fitness for use. This 

warranty shall not apply to products or any part 

thereof which have been subject to accident, negli-

gence, alteration, abuse, or misuse or if damage was 

due to improper installation or use of improper 

power source, or if damage was caused by fire, flood, 

lightning, electrical power surge, explosion, wind 

storm, hail, aircraft or vehicles, vandalism, riot or 

civil commotion, or acts of God. 

L

IMITED

 W

ARRANTY

 

FAAC International, Inc.

 

303 Lexington Avenue 

Cheyenne, WY  82007 

www.faacusa.com 

Summary of Contents for 455 D

Page 1: ...es 10 Learning of Normal Times 10 Learning Times with Gatecoder 10 Automated System Test 11 Logic Tables of 455 D Control Panel 12 Safety in Gate Design 14 Maintenance 14 Limited Warranty 16 T H E 4 5...

Page 2: ...reaker switch and for making sure that the entire gate system meets all applicable electrical codes The installer should refer to the installation manual for a given operator for more information NOTE...

Page 3: ...e each leg of the capacitor supplied to terminals 2 3 Note If you want to delay the closing of one gate leaf in a two leaf gate design be sure to connect its operator to Motor 1 In order to wire motor...

Page 4: ...pplying power to accessories through terminals 17 or 18 and 14 or 15 or 16 on terminal block J1 In most cases this source can be used to power 24 VDC accessories NOTE The 455 D control panel allows a...

Page 5: ...OP_B Partial Opening should illuminate only when an activating signal is sent for 2 and 1 gate leaves respectively STOP should be illuminated except when the stop button is pressed FSWOP and FSWCL sh...

Page 6: ...is set at less than the leaf delay time the delayed leaf closes at the end of the closing time Page 6 November 2003 455 D Control Panel Installation Instructions opening and closing respectively are...

Page 7: ...ls f or opening 1 2 1 2 3 4 5 17 13 19 14 17 Additional Reversing Devices TX RX 1 2 1 2 3 4 5 19 17 12 19 17 Additional Reversing Devices TX RX 1 2 19 12 17 15 Additional Reversing Devices 8 7 Safety...

Page 8: ...and if you release it the value that can be modified with keys and When you reach the last function press the F key to exit the program and the display resumes showing the status of the inputs The tab...

Page 9: ...ed the output functions as a standard indicator light lighted at opening and pause flashing at closing and off when gate closed Different figures correspond to timed activation of the output which can...

Page 10: ...automatically when the opening positive stop is reached and the display stops flashing The procedure has ended and the gate is ready to operate using default slow down automatically set by the control...

Page 11: ...top the operator will automatically shut off An open command must be given to start closing gate operator 2 When gate operator 2 reaches the position that you want it to slow down an open command must...

Page 12: ...t Closed Opens both leaves and closes them after pause time Opens single leaf connected to Motor 1 and closes it after pause time No effect No effect No effect Off Opening Closes both leaves Closes le...

Page 13: ...or 1 No effect opening is inhibited No effect opening is inhibited No effect opening is inhibited Off Opening Stops Stops Stops Stops gate closes when reversing device no longer trig gered No effect O...

Page 14: ...rians should not use a vehicular gate system Prevent such inappropriate use by installing separate gates for pedestrians The operating controls for an automatic gate must be secured to prevent the una...

Page 15: ...Page 15 November 2003 455 D Control Panel Installation Instructions This page is left blank intentionally...

Page 16: ...subject to misuse negligence or accident or has not been operated in accordance with FAAC International Inc s or FAAC S p A s instructions or has been operated under conditions more severe than or oth...