Page 11
November, 2003
455 D Control Panel Installation Instructions
C
OMPLETE
L
EARNING
N
OTES
:
•
If only one gate operator (1) is used, you
must go through the entire programming
procedure, as if you were programming a
gate operator (2). When the gate operator
(1) has finished opening, supply 5 open
commands until the gate operator begins to
close, and then resume normal operations.
Close the gates, enter
“B
ASIC
P
ROGRAMMING
”
, select the
TIME LEARNING function and press the + push-button
for more than 3 seconds: the display begins flashing
and leaf 1 begins opening movement. The following
functions can be commanded by the OPEN A
command (by radio control or key push-button):
•
When gate operator (1) reaches the position
that you want it to slow down, an open
command must be given to start the slow
down phase. When the gate operator
reaches its positive stop, the operator will
automatically shut off.
•
An open command must be given to start
opening gate operator (2).
•
When gate operator (2) reaches the position
that you want it to slow down, an open
command must be given to start the slow
down phase. When the gate operator
reaches its positive stop, the operator will
automatically shut off.
•
An open command must be given to start
closing gate operator (2).
•
When gate operator (2) reaches the position that
you want it to slow down, an open command must
be given to start the slow down phase. When the
gate operator reaches its positive stop, the
operator will automatically shut off.
•
An open command must be given to start closing
gate operator (1).
•
When gate operator (1) reaches the position that
you want it to slow down, an open command must
be given to start the slow down phase. When the
gate operator reaches its positive stop, the
operator will automatically shut off.
The display stops flashing and the gate is ready for normal
operation.
N
OTES
:
•
The open command to slow down the gate should
be given before the gate reaches the positive stop
to prevent the gate from hitting the stop at full
speed. The positive stop could be mistaken for an
obstacle and then upon hitting it, the gate(s) would
automatically reverse on contact.
A
UTOMATED
S
YSTEM
T
EST
When you have finished programming, check if the system is
operating correctly.
Most important of all, check that the force is adequately
adjusted and that the safety devices are operating correctly.
If pressure adjustments on hydraulic operators are not set
before programming. It may need to be reprogrammed for
desired results.