background image

Page 13 

November, 2003 
455 D Control Panel Installation Instructions 

E (Semi-automatic) Logic (455 D) 

Gate Status 

Open A 

Open B 

Stop 

Opening  

Reversing 

Device(s) 

Closing  

Reversing 

Device(s) 

Warning  

Light 

Closed 

Opens both leaves  

Opens single leaf 

connected to  

Motor 1  

No effect 

No effect 

No effect 

Off 

Opening 

Stops 

Stops 

Stops 

Stops; gate closes  

when reversing  

device no longer 

triggered 

No effect 

On 

Opened 

Closes both leaves 

Closes leaf 

Stops 

No effect 

No effect  

(opening is inhib-

ited) 

On 

Closing 

Closes both leaves  

Closes leaf 

Stops 

No effect  

(opening is inhibited) 

Depends on DIP 

switch 4 

Flashes 

Stopped 

Closes the leaves 

Closes the leaf 

No effect 

(opening is 

 inhibited) 

No effect 

No effect  

opening is inhib-

ited) 

On 

Gate Status 

Open A 

Open B 

Stop 

Opening  

Reversing  

Device(s) 

Closing  

Reversing  

Device(s) 

Warning 

Light 

Closed 

Opens both leaves   Opens single leaf 

connected to  

Motor 1  

No effect 

(opening is 

inhibited) 

No effect 

(opening is inhibited) 

No effect (opening 

is inhibited) 

Off 

Opening 

Stops 

Stops 

Stops 

Stops; gate closes 

when reversing  

device no longer trig-

gered 

No effect 

On 

Opened 

Closes both leaves 

Closes leaf  

Stops 

No effect 

No effect (opening 

is inhibited) 

On 

Closing 

Stops 

Stops 

Stops 

No effect  

(opening is inhibited) 

Depends on DIP 

switch 4 

Flashes 

Stopped 

Gate leaves reverse 

direction 

Gate leaf reverses 

direction 

No effect 

(opening is 

inhibited) 

No effect  

(opening is inhibited) 

No effect 

(opening is inhib-

ited) 

On 

EP (Semi-automatic, Step by Step) Logic (455 D) 

Gate Status 

Open A 

Open B 

Stop 

Opening 

Reversing  

Device(s) 

Closing 

Reversing 

Devices(s) 

Warning 

Light 

Closed 

Opens 1 or  

both leaves 

No effect 

No effect 

No effect 

No effect 

Off 

Opening 

No effect 

No effect 

Stops 

No effect 

Stops 

On 

Opened 

No effect 

Closes 1 or  

both leaves 

No effect 

No effect 

No effect 

On 

Closing 

No effect 

No effect 

Stops 

Stops 

No effect 

Flashes 

Stopped 

Opens 1 or  

both leaves 

Closes 1 or  

both leaves 

No effect 

No effect 

No effect 

On 

C (Manned and Constant) Logic (455 D) 

Summary of Contents for 455 D

Page 1: ...es 10 Learning of Normal Times 10 Learning Times with Gatecoder 10 Automated System Test 11 Logic Tables of 455 D Control Panel 12 Safety in Gate Design 14 Maintenance 14 Limited Warranty 16 T H E 4 5...

Page 2: ...reaker switch and for making sure that the entire gate system meets all applicable electrical codes The installer should refer to the installation manual for a given operator for more information NOTE...

Page 3: ...e each leg of the capacitor supplied to terminals 2 3 Note If you want to delay the closing of one gate leaf in a two leaf gate design be sure to connect its operator to Motor 1 In order to wire motor...

Page 4: ...pplying power to accessories through terminals 17 or 18 and 14 or 15 or 16 on terminal block J1 In most cases this source can be used to power 24 VDC accessories NOTE The 455 D control panel allows a...

Page 5: ...OP_B Partial Opening should illuminate only when an activating signal is sent for 2 and 1 gate leaves respectively STOP should be illuminated except when the stop button is pressed FSWOP and FSWCL sh...

Page 6: ...is set at less than the leaf delay time the delayed leaf closes at the end of the closing time Page 6 November 2003 455 D Control Panel Installation Instructions opening and closing respectively are...

Page 7: ...ls f or opening 1 2 1 2 3 4 5 17 13 19 14 17 Additional Reversing Devices TX RX 1 2 1 2 3 4 5 19 17 12 19 17 Additional Reversing Devices TX RX 1 2 19 12 17 15 Additional Reversing Devices 8 7 Safety...

Page 8: ...and if you release it the value that can be modified with keys and When you reach the last function press the F key to exit the program and the display resumes showing the status of the inputs The tab...

Page 9: ...ed the output functions as a standard indicator light lighted at opening and pause flashing at closing and off when gate closed Different figures correspond to timed activation of the output which can...

Page 10: ...automatically when the opening positive stop is reached and the display stops flashing The procedure has ended and the gate is ready to operate using default slow down automatically set by the control...

Page 11: ...top the operator will automatically shut off An open command must be given to start closing gate operator 2 When gate operator 2 reaches the position that you want it to slow down an open command must...

Page 12: ...t Closed Opens both leaves and closes them after pause time Opens single leaf connected to Motor 1 and closes it after pause time No effect No effect No effect Off Opening Closes both leaves Closes le...

Page 13: ...or 1 No effect opening is inhibited No effect opening is inhibited No effect opening is inhibited Off Opening Stops Stops Stops Stops gate closes when reversing device no longer trig gered No effect O...

Page 14: ...rians should not use a vehicular gate system Prevent such inappropriate use by installing separate gates for pedestrians The operating controls for an automatic gate must be secured to prevent the una...

Page 15: ...Page 15 November 2003 455 D Control Panel Installation Instructions This page is left blank intentionally...

Page 16: ...subject to misuse negligence or accident or has not been operated in accordance with FAAC International Inc s or FAAC S p A s instructions or has been operated under conditions more severe than or oth...

Reviews: