RA
DI
O
1-455D115 = 115V
1-455D = 230V
F2
F1
M
M
K
+
OP
-
CL
+24 V
FSW
NC
-
B
-
STOP
A
+
TX
FS W
W. L.
LOCK
9
10 11 12 13 14 15 16 17 18 19
22 23 24 25
LAMP
COM OP
CL
MOTOR 1
MOTOR 2
CL
COM
OP
1
2
3
4
5
6
7
8
20 21
FC
A
1
FC
A
2
F
CC2
F
CC1
V1-4
61C455D
F
-
+
J2
J6
J4
J5
J1
J3
N
L
MAIN
Page 15
November, 2003
400 Operator And
455 D Control Panel Installation Manual
C
ONTROL
P
ANEL
WARNING!
Turn the main power off before
you make any electrical connections or before
programming.
C
AUTION
:
The operators are grounded only by
the grounded circuit the installer provides.
U
SING
A
J
UNCTION
B
OX
If an operator is more than 2 ft away from the control
panel, you must use a junction box for connection.
Use a U. L. Listed cord grip where the operator cord
enters the junction box.
Note: If you have a one-leaf gate design, the
operator must be connected to Motor 1
(terminals 1,2, & 3)
To wire up motor 1, connect the white wire to
terminal 1(on the J4 terminal strip), the black wire to
2, and the red wire to 3. Wire each leg of the capacitor
(supplied) to terminals 2 & 3.
Note: If you want to delay the closing of one gate
leaf in a two-leaf gate design, be sure to connect
its operator to Motor 1.
In order to wire motor 2 in a bi-parting system,
connect the white wire to terminal 4 (on the J4
terminal strip), the black wire to 5, the red wire to 6.
Wire each leg of the capacitor (supplied) to terminals
5 & 6.
C
HECK
THE
M
OTOR
’
S
D
IRECTION
OF
R
OTATION
WARNING! The pressure valves are not preset at
the factory and may operate a gate leaf with
enough force to endanger people and seriously
damage the gate leaf itself.
After you have connected the main power supply, and
the operator(s) to the control panel, you need to
check the direction of rotation for each operator
motor in your gate design.
Note: To check a motor’s direction of rotation,
you must have three closed circuits on terminal
block J1. Install one circuit between terminals 11
and 16, another circuit between terminals 12
and 19, and another circuit between terminals
13 and 19.
Figure 9. The 455 D Control Panel
J3 terminal block for main
power supply
J4 terminal block for
connecting the operator(s)
J1 terminal block for low-
voltage accessories
J2 quick connector port
F Function Push Button
— Programming Push
Button
+ Programming Push
Button
FUSES
220
VAC
115
VAC
F1
Main Power
5 A
10 A
F2
Accessories
800
mA
800
mA
T
HE
455 D C
ON
T
R
OL
P
AN
EL
I
N
ST
A
LLAT
ION
I
NST
R
UC
T
IO
N
S