Page 4
November, 2003
400 Operator And
455 D Control Panel Installation Manual
T
ECHNICAL
D
ATA
400 Model
Parameter
Standard
High Speed
Slow Speed
Long
Model
CBC
2
CBA
3
CBAC
4
SB
1
CBCR
2
CBAR
3
CBACR
4
SBS
1
CBC
2
CBAC
4
Duty type
Apartment, subdivision, industrial, and commercial applications
Duty cycle
80 Cycles/ Hour
Maximum leaf length
5
, ft (m)
18 (5.4)
12 (3.6)
20 (6)
18 (5.4)
Maximum leaf weight, lb (kg)
1300 (600)
900 (400)
2000 (900)
1300 (600)
Maximum leaf swing, deg
115
125
Thrust and traction, lb (kg)
0–1760 (0–800)
90 deg opening time, sec
6
17
12 23
18
Operating temperature range, deg F (deg C)
-33 to 165 (-36 to 75)
Thermal cut out, deg F (deg C)
212 (100)
Hydraulic locking
Opened and/or closed
None
Opened and/or closed
Operator dimensions,
l ´ w ´ h, in. (cm)
40 X 3
5/16
X 3
5/16
(102 X 8.5 X 8.5)
47
1/2
X 3
5/16
X 3
5/16
(121 X 3 X 8.5)
Operator weight, lb (kg)
19 (8.6)
Power voltage required, VAC
7
115 VAC ±10%, 60 Hz, or 230 VAC +6 or -10%, 60 Hz
Amp Draw
115V = 1.5 Amps; 230V = 1 Amp
Type of oil
Lubrication Engineers - MONOLEC 6105
Oil quantity, qt (l)
2
1/3
(2.2) 2
7/8
(2.7)
1
The operator requires external locks.
2
Locks in the extended position. The hydraulic lock is a service device, not a security device.
3
Locks in the retracted position. The hydraulic lock is a service device, not a security device.
4
Locks in both the extended and retracted positions. The hydraulic lock is a service device, not a security device.
5
External locks are recommended if the gate leaves are 12 ft (3.6 m) or longer.
6
The time may vary ±10%.
7 Your standard 220 VAC power source meets the specification for 230 VAC, +6 or -10%.