background image

F S W O P

F S W C L

O P _ A

O P _ B

S T O P

F C A 1

F C A 2

F C C 1

F C C 2

FSWOP

FSWCL

OP_A

OP_B

STOP

FCA1

FCA2

FCC1

FCC2

This display shows the normal 

status of the control panel. 

This display shows the 

meaning of each LED. 

Figure 18.  The 455 D display.

 

P age  17 

M a y, 20 06  

4 1 5 L LS Ope ra tor A nd  
4 5 5  D  C ontrol   Pa ne l  I nsta ll a ti on Ma nua l   

T

HE

 45
5 D C

ONTR

OL

 P

ANE

L

 I

NST

A

LLATION

 I

NSTR

U

C

TI

O

N

S

 

A

CTIVATING

  D

EVICES

 

AND

  R

ADIO

  R

ECEIVER

The 

activating devices and radio receiver for your gate must 

have normally open (N.O.) contacts. Connect such 

devices to terminals 9 and 14. 

 

N

OTE

:

 The FAAC radio receiver plugs into the 5 

prongs labeled J2 (Quick connect port). 

 

Page 19 shows how to connect a three or four wire 

receiver. 

 

D

ECODER

  C

ARD

If you are installing the Digicard 

magnetic card reader, or the Digikey keyboard, use the 

quick-fit connector J2 for the DS decoder card. 

 

N

OTE

If your using both a receiver and decoder, 

hard wire the decoder and plug in the receiver. 

 

O

PEN

/H

OLD

  O

PEN

  D

EVICE

To open and hold open the 

gate, simply maintain a contact across terminals 9 and 

14.  (“A” Mode only) 

  

S

TOP

  B

UTTON

The stop button you install must have 

normally closed (N.C.) contacts. Multiple stop buttons 

must be wired in series. Connect your stop device 

between terminals 11 and 16. 

 

N

OTE

: The 455 D will not operate the motors 

without a closed circuit between 11 & 14. 

 

The LED Indicators

The nine light emitting diodes 

(LEDs) on the control panel can be used to check for the 

proper function of the devices attached to the panel. 

The LED lights are on whenever the contacts are closed 

across each of the respective terminals. 

 

OP_A and OP_B (Partial Opening) should illuminate only 

when an activating signal is sent for 2 and 1 gate leaves, 

respectively. STOP should be illuminated except when 

the stop button is pressed. FSWOP and FSWCL should be 

illuminated except when the reversing devices, for 

 

Figure 17.  

Wiring detail (a) inside 

the junction box and 

(b) from the junction 

box or  operator to the 

high-voltage terminal 

strip on the 455 D 

control panel 

LED 

On 

Off 

OP_A 

Command Given 

No Command  

OP_B 

Command Given 

No Command  

Stop 

 No Command   Command Given 

FSW  
Open 

Opening reversing 

devices clear 

Reversing device 

triggered 

FSW  
Close 

Closing reversing  

devices clear 

Reversing device 

triggered 

FCA1 
FCC1 

Flashes when gate coder is in use.  

Operator 1   

FCA 


FCC 

Flashes when gate coder is in use. 

Operator 2 

U.L. Listed Control Panel Enclosure 

Cord grip or 

conduit from  

U.L. Listed gate 

operator(s) 

(b)

 

Op.1

 

Op.2

 

          

COM  OP  CL  COM  OP  CL 

       

 

J3

 

J4

 

High-voltage 

terminal strip 

455 D Control Panel 

 

Ground

 

J1

 

To the U. L. Listed gate operator

 

To the U.L. Listed 

control panel

 

U.L. Listed 

cord grip 

Junction box 

Legend

 

White

 

Red

 

Black

 

Yellow/ 
Green

 

(a)

 

Conduit to U.L. Listed 

control panel enclosure 

according to N.E.C. 

Summary of Contents for 415 L LS

Page 1: ...the Operator 7 Install the 455 D Control Panel 10 Exploded View 415 L LS 12 415 L LS Parts List 13 The 455 D Control Panel General Description 14 Installing the 455 D Control Panel 14 Connect the Mai...

Page 2: ...affected by the size of the gate how often it is used and how fast the gate operates 2 The operator you choose to install on your gate must be designed for the type and size of your gate and for the...

Page 3: ...ower before making any attempt to repair it 4 Do not attempt to impede the movement of the gate You may injure yourself as a result 5 This equipment may reach high temperatures during operation theref...

Page 4: ...per hour 25 Maximum leaf length ft m 15 4 5 Maximum leaf swing deg 110 Thrust and traction ft lb Nm 221 300 Stroke in cm 15 38 1 Rod speed in sec cm sec 3 4 1 85 Operating Ambient Temperature Deg F De...

Page 5: ...panel 1 415 L LS Operator 1 4 Conductor Electric Cable for Motor Connection 1 3 Conductor Electric Cable for Limit Switch Figure 1 Parts of the 415 L LS Operator Connection 1 Package of mounting hardw...

Page 6: ...rol Panel see page 19 for Basic Programming Reversing devices such as inductive loops and photocells should be installed to provide non contact reversing operation WARNING To insure that the installat...

Page 7: ...he installation of the operator Follow the instructions below to install your operator whether in an inward or outward swinging configuration Installing the operator consists of the following steps At...

Page 8: ...aking sure the dimensions on your gate system match those shown in Figure 9 Outward swinging gate If you are installing the 415 L LS Operator to swing the gate outward construct a steel elbow of suffi...

Page 9: ...nsions 90 deg Swing 110 deg Swing A 7 5 8 in 195 mm 6 5 8 in 170 mm B 7 5 8 in 195 mm 6 5 8 in 170 mm C 50 3 4 in 1290 mm D Maximum 5 in 125 mm 4 2 5 in 110 mm E Less Than A Less Than A ATTACH THE OPE...

Page 10: ...is manual Figure 11 Limit Switch Cover with Fastening Screw ADJUSTING THE LIMIT SWITCHES The limit switch adjustments are carried out as follows 1 Unscrew the upper fastening screw figure 11 ref A and...

Page 11: ...e gate 6 7 8 Operator Wire Gauges for Given Voltage Control Panel Enclosure 115 VAC Photocell A 2 18 AWG A 2 18 AWG Power Switch B 4 14 AWG B 4 14 AWG FAAC 5 Wire Cable for Master Slave Connection and...

Page 12: ...Page 12 May 2006 415 L LS Operator And 455 D Control Panel Installation Manual The 415 L LS Operator 415 L LS...

Page 13: ...Switch Protective Cover 1 12 490108 Limit Switch Assembly 1 13 718354 Front Mounting Pin with C Clips 1 14 N A Self Tapping Screws 4 2 mm x 13 mm 7 15 728271 Front Mounting Bracket 1 16 711027 Limit S...

Page 14: ...g the main power breaker switch and for making sure that the entire gate system meets all applicable electrical codes NOTE An installation is U L compliant only when you install the FAAC operators acc...

Page 15: ...ire to 2 and the red wire to 3 Wire each leg of the capacitor supplied to terminals 2 3 Note If you want to delay the closing of one gate leaf in a two leaf gate design be sure to connect its operator...

Page 16: ...leaves should open If a gate leaf closes then you need to turn off the main power and reverse the connection of the red and black wires on terminal block J4 for the operator controlling that leaf Then...

Page 17: ...he motors without a closed circuit between 11 14 The LED Indicators The nine light emitting diodes LEDs on the control panel can be used to check for the proper function of the devices attached to the...

Page 18: ...elay is desired it must be enabled in the Advance Programming opening and closing respectively are triggered Use the LEDs and the next table to determine if the accessory devices you have installed ar...

Page 19: ...vac Relay Lock 12 19 NC C Coil Voltage Motor Voltage Additional Reversing Devices 17 14 9 NO C 14 If 4 Wire Receiver Free Exit Loop Phone Firebox Hold Open Dev ices 14 9 C NO 1 2 1 2 3 4 5 19 17 12 19...

Page 20: ...am and the display resumes showing the status of the inputs The table on the right shows the sequence of functions accessible in BASIC PROGRAMMING BASIC PROGRAMMING Display Function Default OPERATING...

Page 21: ...UNCTION If this function is enabled the safety devices operate in compli ance with French standard NFP 25 362 Y Enable No Disabled ADVANCED PROGRAMMING To access ADVANCED PROGRAMMING press the F key a...

Page 22: ...sired motor run time has been reached an open command must be given to shut the motor off At this point gate operator 2 will automatically start to open When gate operator 2 reaches the position that...

Page 23: ...r 1 is used you must go through the entire programming procedure as if you were programming a dual gate operating system is being installed 2 When the gate operator 1 has finished opening supply 5 ope...

Page 24: ...g Reversing Device s Warning Light Closed Opens both leaves and closes them after pause time Opens single leaf connected to Motor 1 and closes it after pause time No effect No effect No effect Off Ope...

Page 25: ...ning is in hibited No effect opening is inhibited No effect opening is inhibited Off Opening Stops Stops Stops Stops gate closes when reversing device no longer trig gered No effect On Opened Closes b...

Page 26: ...e system Prevent such inappropriate use by installing separate gates for pedestrians The operating controls for an automatic gate must be secured to prevent the unauthorized use of those controls The...

Page 27: ...NS BUT DOES NOT CLOSE SOLUTION Make sure you have selected the desired operating mode Verify that the reversing devices are working properly FSWOP and FSWCL should be illuminated except when a reversi...

Page 28: ...dance with FAAC International Inc s or FAAC S p A s instructions or has been operated under conditions more severe than or otherwise exceeding those set forth in the specifications for such product s...

Reviews: