![FAAC 415 L LS Installation Manual Download Page 21](http://html1.mh-extra.com/html/faac/415-l-ls/415-l-ls_installation-manual_3105951021.webp)
Page 2 1
M a y, 20 06
4 1 5 L LS Ope ra tor A nd
4 5 5 D C ontrol Pa ne l I nsta ll a ti on Ma nua l
T
HE
45
5 D C
ONT
R
OL
P
ANE
L
I
NS
TA
LL
A
T
IO
N
I
NSTRUCTIONS
F
AIL
S
AFE
:
If this function is activated, it en-
ables a function test of the photo-
cells before any gate movement.
If the test fails (photocells not
serviceable), the gate does not
start the movement.
Y = Enable
No = Disabled
P
RE
F
LASHING
(5
S
):
Activates the flashing lamp for 5s
before start of movement.
Y = Enable
No = Disabled
E
LECTRIC
L
OCK
ON
L
EAF
2:
For using the electric lock on leaf 2
instead of on leaf 1.
Y = Enable
No = Disabled
Display Function Default
I
NDICATOR
-L
ICHT
:
If 0 is selected, the output func-
tions as a standard indicator-light
(lighted at opening and pause,
flashing at closing, and off when
gate closed). Different figures
correspond to timed activation of
the output, which can be used (via
a relay) to power a courtesy lamp.
Time can be adjusted from 0 to
59s in 1s increments, and from
1.0 to 4.1 min. in 10s steps.
0 = Standard Indicator-Light
From 1 to 4.1 = Timed Output
C
LOSING
P
HOTOCELLS
REVERSE
AT
RELEASE
:
Enable this function if
you want the closing photocells to
stop the gate movement and re-
verse it after the beam is cleared.
Default setting is immediate re-
verse.
Y = Enable
No = Disabled
A.D.M.A.P. F
UNCTION
:
If this function is enabled, the
safety devices operate in compli-
ance with French standard NFP
25/362.
Y = Enable
No = Disabled
A
DVANCED
P
ROGRAMMING
To access ADVANCED PROGRAMMING, press the
“F”
key
and, as you hold it down, press the
“+”
key:
•
If you release the
“+”,
the display indicates the name
of the first function.
•
If you release the
“F”
key, too, the display shows the
value of the function that can be modified with keys
“+”
and
“—”.
•
If you press the “F” key (and hold it down), the dis-
play shows the name of the next function, and if
you release it, the value that can be modified with
keys
“+”
and
“—”.
•
When you reach the last function, press the “F” key
to exit the program, and the display resumes show-
ing the status of the inputs.
The table on page 21 and 22 shows the sequence of
functions accessible in
ADVANCED
PROGRAMMING.
ADVANCED PROGRAMMING
+
Display Function
Default
M
AXIMUM
T
ORQUE
AT
I
NITIAL
T
HRUST
:
The motors operate
at maximum torque (ignoring
the torque setting) at start of
movement. Useful for heavy
leaves.
Y = Enable
No = Disabled
L
AST
S
TROKE
AT
C
LOSING
:
The motors are activated at full
speed for 1s to facilitate lock-
ing of the electric lock.
Y = Enable
No = Disabled
R
EVERSING
S
TROKE
:
Before opening, while the gate
is closed, the motors thrust to
close for 2 s thus facilitating
release of the electric lock.
Y = Enable
No = Disabled
L
EAF
2 O
PENING
D
ELAY
(2
S
):
Enables delayed start (at open-
ing) of leaf 2, avoiding interfer-
ence between leaves.
Y = Enable
No = Disabled
F
+