The FAAC 415 L LS Operator is an automatic gate 

operator for a swinging gate leaf. The 415 L LS  

Operator is useful in residential applications and can 

accommodate a gate leaf up to 15 ft (4.5 m) long. 

 

The self-contained 415 L LS Operator consists of an 

electric motor that drives a worm screw housed in an 

aluminum casing.  

 

The locking the 415 L LS Operator provides in the fully 

opened and fully closed positions is a service device 

rather than a security device. Additional, external locks 

are recommended under the following conditions: 

 

∗ 

It is a solid-faced gate. 

∗ 

The installation requires tight security. 

∗ 

The site is subject to vandalism. 

∗ 

The site is subject to strong or very gusty wind 

 

In two-operator gate installations, both (master/slave) 

operators are wired to one control panel. 

 

The electronic control panel is a microprocessor-based 

controller that accepts a wide range of product 

accessories and reversing devices, thus allowing for 

flexible gate system design. 

 

Also for the protection and proper operation of the 415 

L LS Operator, each operator has built in limit switches. 

  

Built-in security and anti-crushing measures of the 415 L 

LS Operator include a torque adjustment that controls 

the force transmitted to the gate leaf through the 415 L 

LS Operator. 

 

The Manual Release mechanism is a key accessed  

device that disengages (or engages) the cylinder on 415 

L LS Operator. When the drive is disengaged, you can 

open and close the gate leaf by hand. Such manual 

operation of the gate is necessary during installation 

and useful during prolonged power failures. 

 

The torque of the 415 L LS Operator is set during Basic 

Programming of the 455 D Control Panel.  (see page 19 

for Basic Programming). 

 

Reversing devices (such as inductive loops and 

photocells) should be installed to provide non-contact 

reversing operation. 

 

WARNING: 

To insure that the installation meets the UL 

325 Standards. A set of photo beam (Part Number 

785163) must be installed anywhere that an entrapment 

with the gate leaf(s) could happen. 

 

During prolonged power outages the manual release 

may be used if needed. 

 
NOTE: The limit switches can be used for two 
options.  
1)  The limit switches can be used as positive 
stops. (basic learning) 

2)  The limit switches can be used as the point 
of slow down and positive stops are required. 
(complete learning) 

Make sure that the gate structure is solidly built. Add 

reinforcing crosspieces if necessary to the gate leaves. 

Make sure that the gate moves smoothly on its hinges 

without excessive friction by swinging it opened and 

closed by hand. If necessary, lubricate all the gate's 

moving parts. 

 

Positive stops are not needed with the 415 L LS 

Operator due to built in limit switches. 

 

M

ANUAL

 R

ELEASE

 M

ECHANISM

 

 

To manual release the 415 L LS Operator perform the 

following steps as shown in Figure 2. 

 

 1.  Slide the key access cover toward the front of the 

operator. 

2.  Insert the key and turn it counterclockwise 1/4 turn. 

I

NSTALLATION

 I

NSTRUCTIONS

 

Installing the 415 L LS Operator involves preparing the 

gate, installing the operator(s), installing the control 

panel, programming control panel, and connecting 

other operational controls. 

 

Note: 

The following installation instructions assume 

you are fully capable of installing an electromechanical 

operator on a gate. This manual does not instruct you 

in designing a gate, installing a gate (whether on 

masonry, wood, or metal posts), or basic electrical 

wiring. The installation tasks discussed in this manual 

are tasks particular to the 415 L LS Operator. 

 

P

REPARE

 

THE

 G

ATE

 

 

Before you install the 415 L LS Operator, you need to 

prepare the gate itself for the operator. Be sure to do 

the following: 

Summary of Contents for 415 L LS

Page 1: ...the Operator 7 Install the 455 D Control Panel 10 Exploded View 415 L LS 12 415 L LS Parts List 13 The 455 D Control Panel General Description 14 Installing the 455 D Control Panel 14 Connect the Mai...

Page 2: ...affected by the size of the gate how often it is used and how fast the gate operates 2 The operator you choose to install on your gate must be designed for the type and size of your gate and for the...

Page 3: ...ower before making any attempt to repair it 4 Do not attempt to impede the movement of the gate You may injure yourself as a result 5 This equipment may reach high temperatures during operation theref...

Page 4: ...per hour 25 Maximum leaf length ft m 15 4 5 Maximum leaf swing deg 110 Thrust and traction ft lb Nm 221 300 Stroke in cm 15 38 1 Rod speed in sec cm sec 3 4 1 85 Operating Ambient Temperature Deg F De...

Page 5: ...panel 1 415 L LS Operator 1 4 Conductor Electric Cable for Motor Connection 1 3 Conductor Electric Cable for Limit Switch Figure 1 Parts of the 415 L LS Operator Connection 1 Package of mounting hardw...

Page 6: ...rol Panel see page 19 for Basic Programming Reversing devices such as inductive loops and photocells should be installed to provide non contact reversing operation WARNING To insure that the installat...

Page 7: ...he installation of the operator Follow the instructions below to install your operator whether in an inward or outward swinging configuration Installing the operator consists of the following steps At...

Page 8: ...aking sure the dimensions on your gate system match those shown in Figure 9 Outward swinging gate If you are installing the 415 L LS Operator to swing the gate outward construct a steel elbow of suffi...

Page 9: ...nsions 90 deg Swing 110 deg Swing A 7 5 8 in 195 mm 6 5 8 in 170 mm B 7 5 8 in 195 mm 6 5 8 in 170 mm C 50 3 4 in 1290 mm D Maximum 5 in 125 mm 4 2 5 in 110 mm E Less Than A Less Than A ATTACH THE OPE...

Page 10: ...is manual Figure 11 Limit Switch Cover with Fastening Screw ADJUSTING THE LIMIT SWITCHES The limit switch adjustments are carried out as follows 1 Unscrew the upper fastening screw figure 11 ref A and...

Page 11: ...e gate 6 7 8 Operator Wire Gauges for Given Voltage Control Panel Enclosure 115 VAC Photocell A 2 18 AWG A 2 18 AWG Power Switch B 4 14 AWG B 4 14 AWG FAAC 5 Wire Cable for Master Slave Connection and...

Page 12: ...Page 12 May 2006 415 L LS Operator And 455 D Control Panel Installation Manual The 415 L LS Operator 415 L LS...

Page 13: ...Switch Protective Cover 1 12 490108 Limit Switch Assembly 1 13 718354 Front Mounting Pin with C Clips 1 14 N A Self Tapping Screws 4 2 mm x 13 mm 7 15 728271 Front Mounting Bracket 1 16 711027 Limit S...

Page 14: ...g the main power breaker switch and for making sure that the entire gate system meets all applicable electrical codes NOTE An installation is U L compliant only when you install the FAAC operators acc...

Page 15: ...ire to 2 and the red wire to 3 Wire each leg of the capacitor supplied to terminals 2 3 Note If you want to delay the closing of one gate leaf in a two leaf gate design be sure to connect its operator...

Page 16: ...leaves should open If a gate leaf closes then you need to turn off the main power and reverse the connection of the red and black wires on terminal block J4 for the operator controlling that leaf Then...

Page 17: ...he motors without a closed circuit between 11 14 The LED Indicators The nine light emitting diodes LEDs on the control panel can be used to check for the proper function of the devices attached to the...

Page 18: ...elay is desired it must be enabled in the Advance Programming opening and closing respectively are triggered Use the LEDs and the next table to determine if the accessory devices you have installed ar...

Page 19: ...vac Relay Lock 12 19 NC C Coil Voltage Motor Voltage Additional Reversing Devices 17 14 9 NO C 14 If 4 Wire Receiver Free Exit Loop Phone Firebox Hold Open Dev ices 14 9 C NO 1 2 1 2 3 4 5 19 17 12 19...

Page 20: ...am and the display resumes showing the status of the inputs The table on the right shows the sequence of functions accessible in BASIC PROGRAMMING BASIC PROGRAMMING Display Function Default OPERATING...

Page 21: ...UNCTION If this function is enabled the safety devices operate in compli ance with French standard NFP 25 362 Y Enable No Disabled ADVANCED PROGRAMMING To access ADVANCED PROGRAMMING press the F key a...

Page 22: ...sired motor run time has been reached an open command must be given to shut the motor off At this point gate operator 2 will automatically start to open When gate operator 2 reaches the position that...

Page 23: ...r 1 is used you must go through the entire programming procedure as if you were programming a dual gate operating system is being installed 2 When the gate operator 1 has finished opening supply 5 ope...

Page 24: ...g Reversing Device s Warning Light Closed Opens both leaves and closes them after pause time Opens single leaf connected to Motor 1 and closes it after pause time No effect No effect No effect Off Ope...

Page 25: ...ning is in hibited No effect opening is inhibited No effect opening is inhibited Off Opening Stops Stops Stops Stops gate closes when reversing device no longer trig gered No effect On Opened Closes b...

Page 26: ...e system Prevent such inappropriate use by installing separate gates for pedestrians The operating controls for an automatic gate must be secured to prevent the unauthorized use of those controls The...

Page 27: ...NS BUT DOES NOT CLOSE SOLUTION Make sure you have selected the desired operating mode Verify that the reversing devices are working properly FSWOP and FSWCL should be illuminated except when a reversi...