When gate operator (2) reaches the positive stop
and the desired motor run time has been
reached, an open command must be given to
shut the motor off. At this point gate operator
(2) will automatically start to close.
•
When gate operator (2) reaches the position that
you want it to slow down, an open command
must be given to start the slow down phase.
•
When gate operator (2) reaches the positive stop
and the desired motor run time has been
reached, an open command must be given to
shut the motor off. At this point gate operator
(1) will automatically start to close.
•
When gate operator (1) reaches the position that
you want it to slow down, an open command
must be given to start the slow down phase.
•
When gate operator (1) reaches the positive stop
and the desired motor run time has been
reached, an open command must be given to
shut the motor off.
The display stops flashing and the gate is ready for
normal operation.
L
EARNING
T
IMES
WITH
L
IMIT
-S
WITCHES
Learning with the Limit-Switches can be done in two
different ways: One way (simple learning)
does not
require positive stops or (complete learning)
which does
require positive stops.
S
IMPLE
L
EARNING
(N
O
P
OSITIVE
S
TOPS
N
EEDED
)
Close the gates, enter
“Basic Programming”,
select the
TIME LEARNING function and press the + push-button for
1 second: the display begins flashing and the leaves
begin the opening movement.
The movement stops automatically when the opening
limit-switch(es) is reached and an activation is required to
get the display stops flashing. Press the “F” button once
more to exit programming, give the panel another “open”
signal.
When the gate operator(s) reaches its limit-switch(es)
time learning is complete.
C
OMPLETE
L
EARNING
(P
OSITIVE
S
TOPS
N
EEDED
)
N
OTES
:
•
If only one gate operator (1) is used, you must
go through the entire programming procedure,
as if you were programming a dual gate
operating system is being installed (2). When
the gate operator (1) has finished opening,
supply 5 open commands until the gate
operator (1) begins to close, and then
resume normal programming procedures.
Close the gates, enter
“B
ASIC
P
ROGRAMMING
”
, select the
TIME LEARNING function and press the + push-
button for more than 3 seconds: the display begins
flashing and leaf 1 begins opening movement. The
following functions can be commanded by the OPEN
A command (by radio control or key push-button):
•
When gate operator (1) reaches the open
limit-switch, it starts to slow down. When
operator (1) reaches its positive stop an
open command must be given to shut the
motor off.
•
When gate operator (1) reaches its positive
stop and has shut off, gate operator (2) will
automatically start to open
•
When gate operator (2) reaches the open
limit-switch, it starts to slow down. When
operator (2) reaches its positive stop an
open command must be give to shut the
motor off.
•
When operator’s (2) motor shuts off it will
automatically start to close.
•
When gate operator (2) reaches the closed
limit-switch, it starts to slow down. When
operator (2) reaches its positive stop an
open command must be given to shut the
motor off.
•
When operator (2) reaches its positive stops
and the motor shuts off, gate operator (1)
will start to close automatically.
•
When gate operator (1) reaches the closed
limit-switch, It starts to slow down. When
operator (1) reaches its positive stop an
open command must be give to shut the
motor off.
The display will stops flashing. Press the “F” button
one last time to return to the status display and the
gate is ready for normal operation.
.
A
UTOMATED
S
YSTEM
T
EST
When you have finished programming, check if the
system is operating correctly.
Most important of all, check that the force is
adequately adjusted and that the safety devices are
operating correctly.
If pressure adjustments on hydraulic operators are
not set before programming. It may need to be
reprogrammed for desired results.