![FAAC 415 L LS Installation Manual Download Page 25](http://html1.mh-extra.com/html/faac/415-l-ls/415-l-ls_installation-manual_3105951025.webp)
Page 25
M a y, 20 06
4 1 5 L LS Ope ra tor A nd
4 5 5 D C ontrol Pa ne l I nsta ll a ti on Ma nua l
E (Semi-automatic) Logic (455 D)
Gate Status
Open A
Open B
Stop
Opening
Reversing
Device(s)
Closing
Reversing
Device(s)
Warning
Light
Closed
Opens both leaves
Opens single leaf
connected to
Motor 1
No effect
No effect
No effect
Off
Opening
Stops
Stops
Stops
Stops; gate closes
when reversing
device no longer
triggered
No effect
On
Opened
Closes both leaves
Closes leaf
Stops
No effect
No effect
(opening is inhib-
ited)
On
Closing
Closes both leaves
Closes leaf
Stops
No effect
(opening is inhibited)
Reverses the gate
immediate
Flashes
Stopped
Closes the leaves
Closes the leaf
No effect
(opening is
inhibited)
No effect
No effect
opening is inhib-
ited)
On
Gate Status
Open A
Open B
Stop
Opening
Reversing
Device(s)
Closing
Reversing
Device(s)
Warning
Light
Closed
Opens both leaves
Opens single leaf
connected to
Motor 1
No effect
(opening is in-
hibited)
No effect
(opening is inhibited)
No effect (opening
is inhibited)
Off
Opening
Stops
Stops
Stops
Stops; gate closes
when reversing
device no longer trig-
gered
No effect
On
Opened
Closes both leaves
Closes leaf
Stops
No effect
No effect (opening
is inhibited)
On
Closing
Stops
Stops
Stops
No effect
(opening is inhibited)
Reverses the gate
immediately
Flashes
Stopped
Gate leaves reverse
direction
Gate leaf reverses
direction
No effect
(opening is in-
hibited)
No effect
(opening is inhibited)
No effect
(opening is inhib-
ited)
On
EP (Semi-automatic, Step by Step) Logic (455 D)
Gate Status
Open A
Open B
Stop
Opening
Reversing
Device(s)
Closing
Reversing
Devices(s)
Warning
Light
Closed
Opens 1 or
both leaves
No effect
No effect
No effect
No effect
Off
Opening
No effect
Stop
Stops
Stops
Stops
On
Opened
No effect
Closes 1 or
both leaves
No effect
No effect
No effect
On
Closing
Stops
No effect
Stops
No effect
Stops
Flashes
Stopped
Opens 1 or
both leaves
Closes 1 or
both leaves
No effect
No effect
No effect
On
C (Manned and Constant) Logic (455 D)
T
HE
455 D
C
ON
TR
OL
P
AN
E
L
I
NS
TALL
ATION
I
NSTR
U
C
TION
S