5
15 AWG
20 AWG
15 AWG
15 AWG
20 AWG
20 AWG
15 AWG
20 AWG
3
11/32”
3
11/32”
4
3/4”
MODEL
CBC
CBAC
SB
SBS
CBAC
R
CBAC
EG
SB
EG
Max Traction / Thrust
Force: (daN)
620
620
620
775
465
465
465
Effective Rod Stroke:
(inches)
10 1/4
10 1/4
10 1/4 10 1/4 10 1/4
15
15
Linear Rod Speed:
(inches/sec)
0.4
0.4
0.4
0.3
0.6
0.6
0.6
Operator Weight: (lbs)
19
19
19
19
19
22
22
Use Frequency:
(cycles/hour)
70
70
70
60
80
50
50
Pump Flow-Rate:
(liters/min)
1
1
1
0.75
1.5
1.5
1.5
Hydraulic Locking:
(
1) = Closing
(2) = Opening and Closing
(1)
(2)
/
/
(2)
(2)
/
Max Leaf Length: (feet)
16
16
18
20
12
18
20
Min Leaf Length: (feet)
9.5
9.5
9.5
12.5
9.5
11.5
11.5
Power Supply
115 VAC ± 10% or 230 VAC +6% -10% 50/60 Hz.
Absorbed Power
220 W
Absorbed Current
1A (230V) or 2A (115V)
Electric Motor
1400 rpm - 4 poles
Thermal Protection
on Windings
248 °F (120°C)
Thrust Capacitor
25uF / 115 V or 8uF / 230 V
Ambient Operating
Temperature Range
-
4°F +131°F (-20 °C +55°C)
Protection Class
IP55
1 DESCRIPTION AND TECHNICAL SPECIFICATIONS
The FAAC Model 400 Swing Gate Operator consists of an
electric pump and a hydraulic piston which transmits drive
to the gate leaf.
Models with hydraulic locking do not require the installation
of electric locks, as they provide mechanical locking of the
leaf when the motor is not operating.
Models without hydraulic locking require the installation of
electric locks to ensure that the leaf is mechanically locked.
FAAC 400 Operators were designed and built to automate
swing leaf gates. Do not use for any other purpose.
Figure 3
1. Operators Mod 400
2. Photocells
3. Electronic control unit
4. Key operated push-button
5. Radio receiver
6. Warning light
7. Electric lock (if necessary)
Table 1: 400 Operator – Technical Specifications
OPERATOR TYPE
STANDARD
EG
A
40 1/2 in
50 1/2 in
B
27 1/2 in
32 1/4 in
C
10 1/4 in
15 in
Always separate low voltage wiring from AC power cables.
Use separate conduits to avoid electrical interference.
The installer is responsible for grounding the gate and opera-
tor systems, for providing the main power breaker switch, and
for making sure that the entire gate system meets all applica-
ble electrical codes.
Make sure to locate all controls that operate the gate system
at least 6 ft away from any moving parts.
Figure 2
Figure 1
400 OPERATOR
1.1 DIMENSIONS
1.2 WIRING