background image

A7

F

+

+

Advanced Programming: 

To access ADVANCED PROGRAMMING, press and hold key F 
and then press key +:

•  Release key +, the unit displays the name of the first 

function.

•  Release key F, modify the value of the function with keys 

+ and -.

•  Press and hold key F, the unit displays the name of the 

next function, and if you release it, the value that can be 
modified with keys + and -.

•  When you reach the last function, press F to exit the pro-

gram, the unit resumes monitoring input status.

The following table shows the sequence of functions 
accessible in ADVANCED PROGRAMMING:

ADVANCED PROGRAMMING

MAXIMUM TORQUE AT INITIAL THRUST:

The motors operate at maximum torque 

(ignoring the torque setting) at start of 
movement. Useful for heavy leaves.

 = Active 

= Disabled

LAST STROKE AT CLOSING:

The motors are activated at full speed for 1 
second to facilitate locking of the electric lock.

 = Active 

=Disabled

REVERSING STROKE:

Before opening, while the gate is closed, 

the motors thrust to close for 2 seconds thus 
facilitating release of the electric lock.

 = Active 

 = Disabled

LEAF 2 OPENING DELAY (2 s):

Enables delayed start (at opening) of leaf 2, 
avoiding interference between leaves.

 = Active 

 = Disabled

FAIL SAFE:

If this function is activated, it enables a 
function test of the photocells before any 
gate movement. If the test fails (photocells 
not serviceable), the gate does not start the 
movement.

 

= Active 

 = Disabled

PRE-FLASHING (5 s):

Activates the flashing lamp for 5 seconds before 
start of movement.

 = Active 

 = Disabled

ELECTRIC LOCK ON LEAF 2:

For using the electric lock on leaf 2 instead 
of on leaf 1.

 = Active 

 = Disabled

INDICATOR-LIGHT:

If 

is selected, the output functions as a 

standard indicator-light (lighted at opening and 
pause, flashing at closing, and off when gate is 

closed). Different figures correspond to the extra 
time compared to normal work time (opening 

or closing) when the output can be used - via a 
relay - to power a courtesy light. Time can be 
adjusted from   to 

 sec. in 1 sec. steps, 

and from    to 

 min. in 10 sec. steps.

   

= Standard indicator-light

from  to 

 =  Timed output

CLOSING PHOTOCELLS REVERSE AT RELEASE:

Enable this function if you want the closing 
photocells to stop movement and reverse at 

release. Default setting is immediate reverse.

 = Active 

 = Disabled

ASSISTANCE REQUEST (combined with next 
function):

If activated, at the end of countdown (settable 
with the next function i.e. “Cycle programming”) 
it affects 8 s of pre-flashing at every Open 

pulse (job request).  Can be useful for setting 
scheduled maintenance jobs.

 = Active 

 = Disabled

CYCLE PROGRAMMING:

For setting countdown of system operation 
cycles. Settable (in thousands) from   to 
thousand cycles. The displayed value is updated 
as cycles proceed.
This function can be used to check use of the 
board or to exploit the “Assistance request”.

A.D.M.A.P. FUNCTION:

When enabled, the safety devices operate in 

compliance with French standard NFP 25/362.

 = Active 

 = Disabled

Exit from programming and return to inputs 
status monitoring.

NOTE

: Parameter modifications take effect immediately. 

Exit out of programming to save changes. If the equipment 

is powered down before returning to normal status monitor-
ing, any unsaved modifications will be lost.

To restore programming defaults, press and hold the 

three b, -, F simultaneously for 5 seconds.

EXTRA WORK TIME:

If reversing occurs, and if the leaf does not 
reach its end contact point, you can activate 
this function to increase work time.

    = Active 

 

  = Disabled

Display

Function

Default

Display

Function

Default

Summary of Contents for 400

Page 1: ...r UL325 Compliant FAAC International Inc Headquarter East Coast Operations 3160 Murrell Road Rockledge FL 32955 Tel 800 221 8278 www faacusa com FAAC International Inc West Coast Operations 357 South...

Page 2: ...nt 8 3 FINAL OPERATIONS 8 4 SYSTEM TEST 9 5 MANUAL OPERATION 9 5 1 Restoring Normal Operating Mode 9 6 OUTWARD OPENING 9 7 POSITIVE STOP ACCESSORY 10 8 MAINTENANCE AND REPAIRS 11 8 1 Oil Level Check 1...

Page 3: ...trians must use a separate entrance SAVE THESE INSTRUCTIONS IMPORTANT SAFETY INFORMATION Important Safety Instructions Gate Construction Vehicular gates should be constructed and installed in accordan...

Page 4: ...I A vehicular gate operator system intended for use in a single family dwelling garage or associated parking area UL325 Gate Operator Classifications COMMERCIAL GENERAL ACCESS VEHICULAR GATE OPERATOR...

Page 5: ...hydraulic piston which transmits drive to the gate leaf Models with hydraulic locking do not require the installation of electric locks as they provide mechanical locking of the leaf when the motor i...

Page 6: ...condition Travel limit mechanical stops must be provided The condition of the structure directly influences the reliability and safety of the automated system The gate must swing level 2 4 INSTALLING...

Page 7: ...m welding slag If the gate structure does not permit the bracket to be firmly fastened modify the structure to create a solid support base 10 Release the operator and manually check that the gate can...

Page 8: ...screw red wording gate closing direction To reduce torque turn screws counter clockwise To increase torque turn screws clockwise Test the bypass adjustment by physically obstructing the gate during it...

Page 9: ...mended Dimensions 5 MANUAL OPERATION If the gate has to be moved manually due to a power failure or a fault in the system use the release device as described below Lift the protective plug Fig 16 Ref...

Page 10: ...43 EG The accessory is mounted on the front flange of the operator using the supplied bolts With the use of the proper square shaped swivel joint sup plied It s possible to limit the rod s travel and...

Page 11: ...nt to not use tools or pry on this piece Now look into the body of the machine and to the left the fluid should be up to the center of the tie rod top for 400 standard or center for 400 EG when the pi...

Page 12: ...per 29 3204425 1 Lt Lobe Pump Part Part Number Description 30 706152 Pump Pin 4x28mm 31 7090010015 O Ring 32 3060 Washer Swivel 33 2069 Swivel Jam Nut 10mm 34 7073095 Swivel Joint square 35 7220355 Fr...

Page 13: ...12 7091015 Piston Rod Seals 13 4350105 Piston Rod Assembly 13a 4350115 Piston Rod Assembly EG Part Part Number Description 14 4994625 Front Flange 15 701829 Front Flange Bolt M5 x 20 mm 16 63000315 Se...

Page 14: ...6 7090290015 O Ring Lock Cylinder 07 7275285 Top Cover 08 7131005 Key Viro 09 7275275 Cover Key 10 7090855 O Ring Extension Receptacle 11 722795 Extension Receptacle 12 7090865 O Ring Base to Body 13...

Page 15: ...01 7171485 Rear Flange 02 417010 Wiring Harness 03 63001005 Cable With Molded Connector 04 7090895 O Ring 21x2 mm 05 7110015 Oil Plug 06 7109135 Cable Strain Relief 07 701479 Screw 3 x 12mm 08 701466...

Page 16: ...le from 0 to 4 min Opening Leaf Delay 2 s can be excluded Thrust Force Adjustable on 50 levels for each motor Terminal Board Inputs Open Open Free Leaf Stop Limit switch Opening Safety Devi ces Closin...

Page 17: ...ragraph on how to connect a monitored device If this input is active when the gate is open it will prevent the leaf closing movement OP FSW Opening safety devices contact N C The opening safety input...

Page 18: ...24V TX FSW 20 21 W L LOCK TX FSW TX FSW 9 10 11 12 13 14 15 16 17 18 19 OPEN A B STP CL OP FSW 24V TX FSW 20 21 W L LOCK 1 2 5 4 3 1 2 RX CL TX CL TX FSW Figure I Connection of One Pair of Monitored...

Page 19: ...ls work in combination with other monitored photocell pro tecting closing or opening entrapment zones In that case they can t be monitored so they can only protect against potential impact on vehicles...

Page 20: ...he key the unit will display the param eter s current value Value can be modified with keys and Press and hold F again the unit will display the name of the next function parameter When you reach the...

Page 21: ...ctions as a standardindicator light lightedatopeningand pause flashing at closing and off when gate is closed Differentfigurescorrespondtotheextra time compared to normal work time opening or closing...

Page 22: ...cessary Note For hydraulic operators like the 400 force should be programmed to maximum level 50 8 Stop leaf movement with a STOP command 9 Release the operators close the leaves and re lock the opera...

Page 23: ...s at closing and leaf 1 begins its closing movement 7 Slow down at closing of leaf 1 8 Leaf 1 stops at closing When the display stops flashing press push button F to exit and save the programming The...

Page 24: ...i t n o c e s a e l e r n o d n a s k c o L g n i n e p o D E K C O L 3 f a e l e h t s e s o l C t c e f f e o N d e l b a s i d N E P O t c e f f e o N t c e f f e o N d e l b a s i d N E P O E c i...

Page 25: ...ediately stops operation NB Effects on other active pulse inputs in brackets P A c i g o L S E S L U P S U T A T S E T A G A N E P O B N E P O P O T S S E C I V E D Y T E F A S G N I N E P O S E C I V...

Page 26: ...TOR 1 MOTOR 2 CL COM OP 1 2 3 4 5 6 7 8 20 21 FCA1 FCA2 FCC2 FCC1 F J2 J6 J4 J5 J3 N L MAIN OP CL 24 V FSW B STOP A TX FSW 9 10 11 12 13 14 15 16 17 18 19 J1 PHOTO OP OPEN DEVICES PHOTO CL 24VDC RX PH...

Page 27: ...O a b a b PHOTO OP a b a b OPEN SAFETY MONITORED CLOSE SAFETY MONITORED PHOTO CL Monitored safety connections The prewired enclosure comes with dedicated terminal blocks for the connection of safety p...

Page 28: ...wired enclosure comes with dedicated terminal blocks for the connection of a relay to drive a Maglock The Maglock kit can be ordered separately as an accessory Refer to this schematic for the connecti...

Page 29: ...1 2 5 Shadow Loop kit option The prewired enclosure comes with dedicated terminal blocks for the connection of a relay and a loop detector socket to implement the shadow loop functionality The Shadow...

Page 30: ...en subject to misuse negligence or accident or has not been oper ated in accordance with FAAC International Inc s or FAAC S p A s instructions or has been operated under conditions more severe than or...