The Slow clocking unit is provided to maintain the synchronization to the base-station timing using a 32Khz
crystal oscillator while the 13Mhz reference clock is switched off. As shown in Figure 35, this unit is composed
of frequency measurement unit, pause unit and clock management unit. Because of the inaccuracy of the 32Khz
oscillator, a frequency measurement unit is provided to calibrate the 32Khz crystal taking the accurate 13Mhz
source as the reference.
Figure 21. Figure 35. The Block Diagram of Slow Clocking unit.
11.
Power, Clocks and Reset
This Chapter descripbes about the power,clock and reset management functions provided by MT6226M.
Together with Power Management IC, MT6226M offers both fine and coarse resolutions of power control
by way of software programming. With this efficient method, the developer can turn on selective resources
accordingly in order to achieve optimized power consumption. The Operating modes of MT6226M as well
as main power states provided by the PMIC are shown in Figure 36.
Figure 36. Major Phone Power States and Operation Modes for MT62
26M
based terminal