Set the battery alarm as a latched or non-latched alarm
If the battery alarm is set to latching then once the battery alarm has been triggered the
Reset Battery Alarm
command needs to be set to reset the latched alarm. If it is set to non-
latching the battery alarm will reset once the battery voltage has increased by .5 volts.
The system default is non-latching:
Command:
Make battery alarm latching
System responds with:
The battery alarm is now latching
Command:
Make battery alarm nonlatching
System responds with:
The battery alarm is now non-latching
Reset a latched Battery Alarm (if set to latching alarm)
Command:
Reset battery alarm
This command is used to clear the Low Battery Voltage alarm, after it has alerted the user
that the voltage has dropped below the set level.
The system responds with:
The
battery alarm has been cleared and will begin to be monitored again
If the alarm is linked to an output the system responds with:
The
battery alarm has been cleared and will begin to be monitored again, the linked output
has also been turned off
If the alarm is not currently set, the system responds with:
The
battery alarm is not currently active and does not need to be cleared
Alive text feature.
This unit has an alive text feature which will send out a alive text as often as it has been
programmed for.
To turn the feature on:
Command: Turn alive text on every xx yy (where xx=1 to 99, yy = hrs or days)
This sets how often the alive text is sent out, XX can be between 1 and 99
Example:
Turn alive text on every 2 days
Every 2 days the Alive text will be sent out
If everything is fine, the system responds with:
This feature has been set, the following text will be sent every xx yy ( yy = hrs or days)
Alive text, battery is currently xx.x volts, signal strength xx %
The default setting will send the Alive text to
All
users, to mask users see page 20
To turn the feature off:
Command: Turn alive text off
If everything is fine, the system responds with:
This feature has been disable