Turn an Output ON or OFF
Command:
Turn OUTPUT NAME on (or) off
(Example: Turn Generator on)
If everything is fine, the system responds with:
OUTPUT NAME
has been turned off (or) on
This command is used to turn on/off Outputs. If the item named is not an Output or the
command is not spelt correctly the system responds with:
Sorry either that output does not exist or the options ON or OFF has not been use
Turn an Output ON for XX mins or hrs or days
Command:
Turn OUTPUT NAME on for XX (either mins or hrs or days)
If everything is fine, the system responds with:
OUTPUT NAME
has been turned on for XX (mins or hrs or days)
XX can be between 1 to 99 either minutes or hours or days (max time 99 days)
If no time is specified then the output will be turned on until the “Turn output Off “ command is
sent
The Output on time XX can also be p
rogrammed so when ever the “Turn output On
command is sent the output will turn on for the programmed time
Command:
Set OUTPUT NAME on time to XX (mins or hrs or days)
If everything is fine, the system responds with:
The OUTPUT NAME on time has been set to XX (mins or hrs or days)
If no value is set the system will respond with:
The OUTPUT NAME has been turned on and will stay on because no time-out value
was set
If the text mins or hrs or days does not follow the XX (time) the system will respond with:
Sorry you can only set mins, hrs or days please check the spelling and try again
Change Output to Normally On or Normally Off
Command:
Make OUTPUT NAME inverted
This command is used to define if the output relay is normally open or normally closed.
System default is normally open.
The system responds with:
The
OUTPUT NAME
is now inverted
To non-invert the output:
Command:
Make OUTPUT NAME noninverted
The system responds with:
The OUTPUT NAME is now noninverted
Ezy Switch SMS-T4 Installation & Operation