System Monitor 

Installation Manual 

 

 

Summary of Contents for SMS-T4

Page 1: ...EZY SWITCH LIMITED SMS T4 System Monitor Installation Manual ...

Page 2: ...t 13 Get linked information 13 Setup Input Tick off 13 Programming the Input reply message 14 Turn an Output ON or OFF 15 Turn an Output ON for a set time 15 Invert Output 15 Make an Output Pulse On and Off 16 Clear Output Pulse Set to non pulsed 16 Turn Output response On Off 17 Save Output Status 17 Linking Outputs 17 Set Battery Alarm trigger voltage 18 Link Battery Alarm to Output 18 Check Bat...

Page 3: ...ed Inputs o Programmable for Normally Open or Normally Closed Outputs Inputs and Outputs names are user programmable via text command up to 20 characters Link any Input to any Output Example Link intruder sensor or smoke detector input to light or alarm horn output Monitors battery supply voltage and sends alarm message if low battery is detected at below the programmed alarm setting On demand upd...

Page 4: ...ion Outputs Max Input voltage 12 to 30 Volts DC 800mA 40 Milli amps 10 years without power Relay 3 A resistive 125VAC 30vdc SMS T4 Terminal Electrical Connections Terminal 1 Batt Terminal 2 Batt also sensor GND Terminal 3 5vdc supply for sensor Terminal 7 Ouput 1 Terminal 4 Variable voltage in from sensor Terminal 8 Output 1 Terminal 5 Input 1 Terminal 9 Output 2 Terminal 6 Input 1 Terminal 10 Out...

Page 5: ... Manual Important Note A registered electrician must be used when connecting to the 120 240v main supply voltage Relay 2 Connection Internal Relay Relay Terminals 9 10 Relay 1 Connection Internal Relay Relay Terminals 7 8 Relay 3 Connection Internal Relay Relay Terminals 15 16 Relay 4 Connection Internal Relay Relay Terminals 17 18 ...

Page 6: ... Switch SMS T4 Installation Operation Manual Switch 10 30vdc Input 1 Terminal 6 Input 2 Terminal 12 Input 3 Terminal 14 Fig 2a Fig 2b Terminal 5 Switch Input1 Terminal 6 Switch Input3 Terminal 11 Switch Input2 Terminal 12 Terminal 13 Terminal 14 SMS T4 Pressure sender 5vdc Red Fig 1 Sensor In Green GND Black Terminal 3 5vdc supply for the sensor Terminal 4 variable voltage from the sensor ...

Page 7: ...mber without the preceding 0 If the users number is 0414884900 then Command add user 65414884900 USA Canada 001 1 and the Area Code Number If the users number is 414 555 1434 then Command add user 14145551434 IMPORTANT Ezy Switch SMS T4 Installation Operation Manual NOTE If a user sends a text message to the system which is not an exact match with the commands the system responds with Sorry either...

Page 8: ... number XXXXXXXX has been added to the user list Removing a User Command Remove user XXXXXXXX see Country Code page 7 If you try to remove the only user the system responds with Cannot delete the only user If the number sent is not currently on the list the system responds with XXXXXXXX is not currently in the user list so cannot be removed please check the number and try again If everything is ok...

Page 9: ... unit using the Add User command as per above If User lookup is Off the SMS T4 will respond to any number that sends the correct command The system responds with The user lookup list feature has been turned on and the unit will only accept commands from programmed users OR The user lookup list feature has been turned off and the unit will only accept commands from any numbers PLEASE NOTE Input cha...

Page 10: ... system responds with Battery is currently volts signal strength is run test now The unit will now test the inputs and outputs and waits for the inputs to be triggered When input1 is turned on output1 will turn on when input1 is turned off output1 will turn off When input2 is turned on output2 will turn on when input2 is turned off output2 will turn off When input3 is turned on output3 will turn o...

Page 11: ...rename is not currently in the list the system responds with Sorry either that device does not exist or the message format is not understood please check the spelling and try again If the new name chosen does not fulfill the requirements of a name the system responds with Sorry that name is not allowed please check that it is between 1 and 20 characters long If everything is ok the system responds...

Page 12: ...nlatching Example Make alarm non latching This sets the Input to a NON latched Input and the system responds with The Input INPUT NAME is now a nonlatching input Reset a latched Input used to return Input to non activated state Command Reset INPUT NAME Example Reset alarm The system responds with INPUT NAME is no longer in a latched state and will begin to be monitored again If the Input is not la...

Page 13: ...The inputs can have a Tick Off feature if this feature is turned on and an input is on the unit will send a reminder text every 5 minutes until the text command Tick INPUT NAME off is sent max number of texts 20 To turn the feature on Command Make INPUT NAME tickoff on If everything is fine the system responds with The input tickoff feature has been turned on To turn the feature off Command Make I...

Page 14: ...ter using The Command for Input1 is Message3 please close the gate after using The Command for Input2 is Message4 please close the gate after using If everything is fine the system responds with The reply message has been set to please close the gate after using To turn the feature off and set back to factory settings simply send The Command for Input1 is Message1 The Command for Input2 is Message...

Page 15: ... also be programmed so when ever the Turn output On command is sent the output will turn on for the programmed time Command Set OUTPUT NAME on time to XX mins or hrs or days If everything is fine the system responds with The OUTPUT NAME on time has been set to XX mins or hrs or days If no value is set the system will respond with The OUTPUT NAME has been turned on and will stay on because no time ...

Page 16: ...been set as per above the defalt time is 3 seconds and the system responds with OUTPUT NAME is now a pulsing output with a defalt pulse time of 3 seconds If the Output was initially On when the Output was set the system responds with OUTPUT NAME is now a pulsing output and has been turned off in preparation for use If the Output is linked to an Input when the Input is triggered the system sends IN...

Page 17: ...e power was turned off then when the power is restored the output will turn back on Note this does not apply if an output was turned on for a specified time System default is not saved Command Make OUTPUT NAME save The system responds with The output condition will be saved and restored if the power is reset To turn the feature off Command Make OUTPUT NAME nonsave The system responds with The outp...

Page 18: ...the alarm has been reset If the value XX X is outside the settings the system responds with Because the value is out of range the voltage alarm has been set to 11 5 volts and the alarm has been reset Link the Battery Alarm to an Output Command Link battery alarm to OUTPUT NAME The system responds with The battery alarm has successfully been linked to OUTPUT NAME and the alarm has been reset To cle...

Page 19: ... the system responds with The battery alarm has been cleared and will begin to be monitored again the linked output has also been turned off If the alarm is not currently set the system responds with The battery alarm is not currently active and does not need to be cleared Alive text feature This unit has an alive text feature which will send out a alive text as often as it has been programmed for...

Page 20: ...alive text If everything is fine the system responds with The number has been added to the alive text list Setting priority inputs When the priority feature is turned on the inputs will have a priority associated to them input 1 has the highest and input 4 the lowest For example in input 3 is turned on only inputs 1 or 2 can activate inputs 4 will not activate and be ignored so only a higher input...

Page 21: ...he scale for percentages Method 2 Five Point Fill the tank to the required low level then send Command Set low level The system responds with Tank low level has been set Fill the tank to the required 1 4 level then send Command Set 1 4 level The system responds with Tank 1 4 level has been set Fill the tank to the required 1 2 level then send Command Set 1 2 level The system responds with Tank 1 2...

Page 22: ...evels Note If the reset level is not set the default alarm reset level will be 10 great than the low alarm set level and 10 less than the high alarm level Command Set xxxx litres yyy alarm reset OR Command Set xxxx gallons yyy alarm reset where xxxx is the litres gallons yyy is either low or high The system responds with The automatic alarm reset level has been set to xxxx litres or gallons Turnin...

Page 23: ...ts or gals yyy where xxx will be the litres or gallons and yyy will be the percentage e g Tank volume is 1200 lts 68 OR Tank volume is 1200 gals 68 Get Firmware Version Command Ver The system responds with SMS T4 Ver X X Get Signal Strenth Command Sig The system responds with Currently the signal strength is XX Resetting the Unit Command Reboot The system responds with Module is now resetting Rese...

Page 24: ...replaced product as its property The equipment has been installed correctly and is used in accordance with the instructions issued with the product In no event will Penguin Electronics Ltd or its agents accept any liability for any direct indirect or consequential losses or damages whatsoever or howsoever arising from the use of the product Where conditions or warranties are implied or other right...

Page 25: ...ssage Input Name has been turned on If the input turns back off before the programmed time delay expires the input is reset and the time starts back at zero If the input is linked to an output it will also state the linked output has also been turned on Off Delay This delay is used when the input turns OFF Example If input1 has an OFF delay of 10mins when Input1 turns OFF the unit will wait 10 min...

Page 26: ...ifferent location 3 SIM card not installed 4 SIM has a pin number remove 5 SIM is locked remove lock LED slow flashes every 3 seconds But no texts are sent or received The unit can find the GSM network hence the slow flashes but the signal strength is to low 1 Replace aerial with high gain aerial 2 Move unit to different location 3 SIM card NOT registered with the network provider 4 No credit on t...

Page 27: ... gallons Where YYY is either litres or gallons e g set 30000 litres Send Set xxx YYY low alarm this is the tank level that you want the pump to turn on at Where YYY is either litres or gallons e g set 1000 litres low alarm Send Set xxx YYY low alarm reset this is the tank level that you want the pump to turn off at Where YYY is either litres or gallons e g set 29000 litres low alarm Send Add user ...

Page 28: ...nected To The Pump SMS 2 Pump controller Send the following commands Send Set user Send Set pump mode Send Add user xxxxxxxxxxxx this is the number of the sim card in the tank controller SMS T4 See page 8 of the manual Adding a user If you want to add more users you can do so after the above commands Note Connect the pump to output1 Finish Once you are happy with the system you can stop the tank l...

Page 29: ...please check Tank Controller After receiving the refresh txt the SMS 2 pump controller will reply to the SMS T4 if the SMS T4 does not receive this reply after 10 attempts it will send the users the following text The unit has tried 10 time to reach the pump controller and not had a reply please check the pump controller Default mode for this feature is Off If you require this feature then send th...

Page 30: ...30 Float Mode Pump Operation ...

Page 31: ... the SMS 2 which turns the pump On when the tank reset level is reached a text is send to the SMS 2 to turn the pump Off Monitors low and high points with float switches when the low float switch turns On a text is sent to the SMS 2 which turns the pump On when the high float switch turns On a text is send to the SMS 2 to turn the pump Off SMS T4 Tank High Float Switch Low Float Switch ...

Page 32: ... All technologies design and Intellectual property is owned by Penguin Electronics Ltd New Zealand Version 2 3 ...