Page | 62
Before continuing, confirm the key
ed switch is in the ‘
Power Off
’ position and that the emergency stop
switch is pushed in.
20.3.5.
Using FIG. 20.3 as a guide, plug previously removed wires back into batteries.
20.3.5.1.
Connect the red #10AWG to the positive terminal of Battery 2.
20.3.5.2.
Connect the short single black #10AWG wire of the splitter with the 2 black wires
to the positive terminal of Battery 1.
20.3.5.3.
Connect opposite end with 2 black wires (one #10AWG and one #16AWG) to
Battery 2 negative terminal.
20.3.5.4.
Connect the White #10AWG wire, to the negative terminal of Battery 1.
20.3.5.5.
Reconnect the 120VAC power cord to the 120VAC outlet. Turn keyed switch to the
‘
Power On
’ position, and pull Emergency Stop button out.
20.3.5.6.
Cycle VPL up and down several inches to confirm proper battery function
WHITE #10AWG
BLACK #10AWG
BLACK #16AWG
RED #10AWG
=
=
=
=
NEGATIVE/GROUND WIRE, GROUND CIRCUIT FOR MOTOR
BATTERY PARALLEL JUMPER WIRE, CREATES 24VDC FOR MOTOR
12VDC POWER FOR CONTROL CIRCUIT
POSITIVE/HOT WIRE, MOTOR CIRCUIT
FIG. 20.3