HC 404 System • Operation
43
HCR 102 Reset Mode Summary — Front Panel-Based Resets
Mode
Use This
Mode to...
Activation
Result
Run/Stop
Pr
ogram
Toggle stop/start
program
To stop or start a program:
1.
Hold down the
Reset
button for about 3 seconds,
until the
Power
LED blinks once.
2.
Release and press the
Reset
button momentarily
(for <1 second) within 1 second*.
* Nothing happens if the momentary press does not
occur within 1 second.
The LED flashes 2 times if the program is
starting.
The LED flashes 3 times if the program is
stopping.
NOTE:
This mode is available only
via
front panel
.
Reset All IP Settings
Reset IP settings
and port maps
to factory
defaults without
affecting user-
loaded files
To reset all IP settings:
1.
Hold down the
Reset
button for about 6 seconds
until the
Power
LED blinks twice (once at 3 seconds,
again at 6 seconds).
2.
Release and press the
Reset
button momentarily
(for <1 second) within 1 second*.
* Nothing happens if the momentary press does not
occur within 1 second.
Reset All IP Settings mode:
•
Sets the LAN IP address back to factory
default (192.168.254.250)
•
Sets the subnet back to factory default
(255.255.255.0)
•
Sets the default gateway address to the
factory default (0.0.0.0)
•
Sets domain and host names to factory
default
•
Sets port mapping back to factory default
•
Turns DHCP off
•
Turns events (user-created schedules,
macros) off.
NOTE:
This mode is available only
via
front panel
.
Reset to Factory Defaults (Absolute System Reset)
Start over with
configuration
and uploading
To reset the unit to all factory default settings
via front panel
:
1.
Hold down the
Reset
button for about 9 seconds
until the
Power
LED blinks three times (once at 3
seconds, again at 6 seconds, again at 9 seconds).
2.
Release and press the
Reset
button momentarily
(for <1 second) within 1 second*.
* Nothing happens if the momentary press does not
occur within 1 second.
Reset to Factory Defaults mode performs
a complete reset to factory defaults
(except the firmware).
•
Resets all AV settings.
•
Does everything Reset All IP Settings
mode does
•
Removes (clears) all user-loaded files and
configurations from the HCR 102:
•
Clears driver-port associations (IR,
serial, Ethernet) and port configurations
•
Removes schedules, settings, macros
•
Removes the factory default GC
configuration. The basic GC configuration
project can be downloaded from the
Extron website if you want to restore it to
the unit after a reset.
NOTE:
This mode is available via
front
panel, Toolbelt, and PCS
.
The preferred methods for starting this
reset are
front panel and Toolbelt
.
In PCS this mode is called “Reset All
Settings and Delete Files.”
This is also known as an absolute
system reset.
NOTE:
After performing a Reset All IP Settings or Reset to Factory Defaults reset, set the IP address again
(by using the OSD menu, Toolbelt, or PCS) for use on your network.