DTP2 T/R 211 • Reference Information
30
Reference Information
This section provides procedures for mounting the DTP2 211 transmitter and receiver and
disconnecting the ground between them.
•
Mounting the Transmitter or Receiver
•
Mounting the Transmitter or Receiver
ATTENTION:
•
Risk of property damage:
•
Risque de dommages matériels :
•
Installation and service must be performed by authorized personnel only.
•
L’installation et la maintenance du système doivent être exclusivement
effectuées par le personnel autorisé.
•
Avoid ground potential differences between the transmitter and receiver
installation sites, which can lead to
equipment damage
or a missing or
unstable picture. If a potential difference cannot be avoided, remove the ground
connection between the units and locally power both units (see
•
Évitez les différences de potentiel de mise à la terre entre les sites d’installation
d’émetteur et de récepteur de commutation, qui pourraient endommager
l’équipement ou rendre l’image invisible ou irrégulière. Si une différence de
potentiel ne peut être évitée, enlevez la connexion de mise à la terre entre les
unités et alimentez les deux unités localement (voir
à la
The 1‑inch high, quarter rack width, 6‑inches deep transmitter and receiver can be placed
on a table, mounted in a rack, or mounted under a desk or table. The receiver can also be
mounted on a projector bracket.
Tabletop Mounting
Attach the provided rubber feet to the bottom four corners of the enclosure.
Mounting Kits
Mount the unit using the optional compatible mounting kit listed on the Extron
, in
accordance with the directions included with the kit. The devices are compatible with the
Extron Half Rack shelf system HRB
109, Extron UTS under the table shelf system, Extron
rack shelves RSU
126, and MBU
125 under the table shelf brackets.