DTP2 T/R 211 • Remote Control
21
ASCII to Hex Conversion Table
•
Space
Figure 14. ASCII to Hex Conversion Table
Symbol Definitions
]
= Carriage return with line feed
|
or
}
= Pipe character or carriage return (no line feed) can be used interchangeably.
• = Space character
W or
E
= W or Escape key can be used interchangeably.
X!
= Input or Output
X@
= Verbose mode
0
= Clear/none
1
= Verbose mode (default)
2
= Tagged responses for queries
3
= Verbose mode and tagged responses for queries
X#
= Text string of up to 24 characters
Default =
DTP2‑T‑211
or
DTP2‑R‑211
Alphanumeric characters and hyphens only
No distinction between upper and lower case
No spaces
First character must be a letter and the last character cannot be a hyphen
X$
= Firmware version to the second decimal place
X%
= Audio input
0
= Auto (default)
1
= Digital
2
= Analog
X^
= Remote power
0
= No remote power (Off)
1
= DTP2 48 VDC (On)
X*
= Audio toggle switch
1
= DOWN —De‑embedded audio from the HDMI signal is output on the analog audio
output (default).
2
= UP — Analog audio passed from the TX is output on the analog audio output.
14