background image

 

Safety Instructions

Safety Instructions • English

 WARNING:

  This symbol,  , when used on the product, is 

intended to alert the user of the presence of uninsulated 
dangerous voltage within the product’s enclosure that may 
present a risk of electric shock

.

ATTENTION:

 This symbol,  , when used on the product, is 

intended to alert the user of important operating and 
maintenance (servicing) instructions in the literature provided 
with the equipment.

For information on safety guidelines, regulatory compliances, EMI/EMF 
compatibility, accessibility, and related topics, see the Extron Safety and 
Regulatory Compliance Guide, part number 68-290-01, on the Extron 
website, 

www.extron.com

.

Sicherheitsanweisungen • Deutsch

WARNUNG:

 

Dieses Symbol   auf dem Produkt soll den 

Benutzer darauf aufmerksam machen, dass im Inneren 
des Gehäuses dieses Produktes gefährliche Spannungen 
herrschen, die nicht isoliert sind und die einen elektrischen 
Schlag verursachen können.

VORSICHT:  

Dieses Symbol   auf dem Produkt soll dem 

Benutzer in der im Lieferumfang enthaltenen Dokumentation 
besonders wichtige Hinweise zur Bedienung und Wartung 
(Instandhaltung) geben.

Weitere Informationen über die Sicherheitsrichtlinien, 
Produkthandhabung, EMI/EMF-Kompatibilität, Zugänglichkeit und 
verwandte Themen finden Sie in den Extron-Richtlinien für Sicherheit 
und Handhabung  (Artikelnummer 68-290-01) auf der Extron-Website, 

www.extron.com

.

Instrucciones de seguridad • Español

ADVERTENCIA: 

Este símbolo,  , cuando se utiliza en el producto, 

avisa al usuario de la presencia de voltaje peligroso sin aislar 
dentro del producto, lo que puede representar un riesgo de 
descarga eléctrica.

ATENCIÓN:

 

Este símbolo,  , cuando se utiliza en el producto, 

avisa al usuario de la presencia de importantes instrucciones 
de uso y mantenimiento recogidas en la documentación 
proporcionada con el equipo.

Para obtener información sobre directrices de seguridad, cumplimiento 
de normativas,  compatibilidad electromagnética, accesibilidad y 
temas relacionados, consulte la  Guía de cumplimiento de normativas 
y seguridad de Extron, referencia 68-290-01, en el sitio Web de Extron, 

www.extron.com.

Instructions de sécurité • Français

AVERTISSEMENT:

 

Ce pictogramme,  , lorsqu’il est utilisé 

sur le produit, signale à l’utilisateur la présence à l’intérieur 
du boîtier du produit d’une tension électrique dangereuse 
susceptible de provoquer un choc électrique.

ATTENTION

 Ce pictogramme,  , lorsqu’il est utilisé sur le produit, 

signale à l’utilisateur des instructions d’utilisation ou de 
maintenance importantes qui se trouvent dans la documentation 
fournie avec le matériel.

Pour en savoir plus sur les règles de sécurité, la conformité à la 
réglementation, la compatibilité EMI/EMF, l’accessibilité, et autres sujets 
connexes, lisez les informations de sécurité et de conformité Extron, réf. 
68-290-01, sur le site Extron,

 www.extron.com

.

Istruzioni di sicurezza • Italiano 

AVVERTENZA: 

Il simbolo, 

, se usato sul prodotto, 

serve ad avvertire l'utente della presenza di tensione 
non isolata pericolosa all'interno del contenitore 
del prodotto che può costituire un rischio di scosse 
elettriche.

ATTENTZIONE: 

Il simbolo, 

, se usato sul prodotto, 

serve ad avvertire l'utente della presenza di importanti 
istruzioni di funzionamento e manutenzione nella 
documentazione fornita con l'apparecchio.

Per informazioni su parametri di sicurezza, conformità alle normative, 
compatibilità EMI/EMF, accessibilità e argomenti simili, fare riferimento 
alla Guida alla conformità normativa e di sicurezza di Extron, cod. 
articolo 68-290-01, sul sito web d

Extron, 

www.extron.com

.

Instrukcje bezpieczeństwa • Polska

OSTRZE

Ż

ENIE: 

Ten symbol,

 

,

 gdy używany na produkt, ma 

na celu poinformować użytkownika o obecności izolowanego i 

niebezpiecznego napięcia wewnątrz obudowy produktu, który 

może stanowić zagrożenie porażenia prądem elektrycznym.

UWAGI: 

Ten symbol, 

, gdy używany na produkt, jest 

przeznaczony do ostrzegania użytkownika ważne operacyjne 

oraz instrukcje konserwacji (obsługi) w literaturze, wyposażone 

w sprzęt.

Informacji na temat wytycznych w sprawie bezpieczeństwa, regulacji 

wzajemnej zgodności, zgodność EMI/EMF, dostępności i Tematy 

pokrewne, zobacz Extron bezpieczeństwa i regulacyjnego zgodności 

przewodnik, część numer 68-290-01, na stronie internetowej Extron, 

www.extron.com

.

Инструкция по технике  
безопасности 

 Русский

ПРЕДУПРЕЖДЕНИЕ: 

Данный символ,  , если указан 

на продукте, предупреждает пользователя о 
наличии неизолированного опасного напряжения 
внутри корпуса продукта, которое может привести к 
поражению электрическим током.

ВНИМАНИЕ:  

Данный символ,  , если указан на 

продукте, предупреждает пользователя о наличии 
важных инструкций по эксплуатации и обслуживанию в 
руководстве, прилагаемом к данному оборудованию.

Для получения информации о правилах техники 
безопасности, соблюдении нормативных требований, 
электромагнитной совместимости (ЭМП/ЭДС), возможности 
доступа и других вопросах см. руководство по безопасности 
и соблюдению нормативных требований Extron на сайте 
Extron: 

www.extron.com

, номер по каталогу - 68-290-01.

安全说明

 

 

简体中文

警告

产品上的这个标志意在警告用户该产品机壳内有暴露的危险 

电压,有触电危险。

注 意

产品上的这个标志意在提示用户设备随附的用户手册中有 

重要的操作和维护(维修)说明。

关于我们产品的安全指南、遵循的规范、

EMI/EMF 

的兼容性、无障碍 

使用的特性等相关内容,敬请访问 

Extron 

网站 

www.extron.com

,参见 

Extron 

安全规范指南,产品编号 

68-290-01

Summary of Contents for DTP CrossPoint 108 4K

Page 1: ...68 2368 51 Rev B 10 19 DTP CrossPoint 4K Series Scaling Presentation Matrix Switcher Matrix Switcher Setup Guide...

Page 2: ...encia 68 290 01 en el sitio Web de Extron www extron com Instructions de s curit Fran ais AVERTISSEMENT Ce pictogramme lorsqu il est utilis sur le produit signale l utilisateur la pr sence l int rieur...

Page 3: ...t Field FlexOS Glitch Free Global Configurator Global Scripter GlobalViewer Hideaway HyperLane HyperLane IP Intercom IP Link Key Minder LinkLicense LockIt MediaLink MediaPort NetPA PlenumVault PoleVau...

Page 4: ...lded twisted pair UTP or shielded twisted pair STP cables but to ensure FCC Class A and CE compliance STP cables and STP Connectors are required La technologie extension paires torsad es fonctionne av...

Page 5: ...sponses mentioned in this guide the character 0 is used for the number zero and O is the capital letter o Computer responses and directory paths that do not have variables are written in the font show...

Page 6: ......

Page 7: ...ng and Adjusting Volume and Mic Volume 19 Setting the Front Panel Locks Executive Modes 20 Selecting Lock Mode 2 or Toggling between Mode 2 and Mode 0 21 Selecting Lock Mode 2 or Toggling between Mode...

Page 8: ...viii DTP CrossPoint 4K Series Contents...

Page 9: ...ide provides instructions for an experienced installer to set up and operate the Extron DTP CrossPoint 4K Series matrix switchers Step by step instructions show you how to Connect the hardware see Rea...

Page 10: ...Tx Rx Tx Rx G OVER TP XTP DTP HDBT SIG LINK OUT SIG LINK OUT 7 8 RS 232 IR Tx Rx Tx Rx XTP DTP HDBT G RS 232 IR Tx Rx Tx Rx G OVER TP 1 OUTPUTS AUDIO Tx Rx G Tx Rx RS 232 IR OVER DTP OUTPUTS AUDIO Tx...

Page 11: ...N port IPCP models or LAN port non IPCP models a serial port or a USB port connection using either the Extron Product Configuration Software DSP Configurator software or the Simple Instruction Set SIS...

Page 12: ...MP OUTPUT AUDIO INPUTS DMP EXPANSION INPUTS OUTPUTS RS 232 IR Tx Rx Tx Rx G RS 232 IR Tx Rx Tx Rx G XTP DTP XTP DTP 10 OVER TP RS 232 IR Tx Rx Tx Rx G 1 L R 1 L R 3 L R 3 L R 5 L R 2 L R 4 L R 2 L R 4...

Page 13: ...LockIt HDMI Cable Lacing Bracket B TP XTP DTP switches see figure 2 and figure 3 XTP DTP ATTENTION Position this switch BEFORE connecting the appropriate device to the TP connector Failure to comply...

Page 14: ...Ne pas respecter cette proc dure pourrait endommager le point de connexion The following table identifies the outputs with TP switches by matrix size Matrix Outputs Matrix Outputs 10x8 5B 6B 7 8 8x6 3...

Page 15: ...Tx Rx G OVER TP OVER TP INPUTS OUTPUTS 3B Tx Rx G REMOTE SIG LINK OUT SIG LINK OUT SIG LINK IN SIG LINK IN 48V MIC LINE 1 1 3 2 4 2 3 4 LINK EXP AUDIO OUTPUTS AUDIO INPUTS DMP EXPANSION 1 L R 1 L R 3...

Page 16: ...Extron DMP 128 ProDSP Digital Matrix Processor Link LED Lights to indicate that the port is connected to a compatible device Serial and IR Insertion Connections RS 232 IR Tx Rx Tx Rx G DTP CROSSPOINT...

Page 17: ...orts outputs 5B 6B 7 and 8 see figure 6 RS 232 IR Tx Rx Tx Rx G and figure 7 Plug signals modulated IR signals or both into these serial RS 232 3 5 mm 5 pole captive screw connectors to insert bidirec...

Page 18: ...er via this 3 5 mm 3 pole captive screw connector for remote control of the switcher see RS 232 and IR connectors on page 15 to wire the connector Switcher Reset 50 60 Hz 100 240V A MAX RESET DTP CROS...

Page 19: ...DTP HDBT 7 8 XTP DTP HDBT RS 232 IR Tx Rx Tx Rx G RS 232 IR Tx Rx Tx Rx G OVER TP RS 232 IR Tx Rx Tx Rx G RS 232 IR Tx Rx Tx Rx G OVER TP SIG LINK OUT SIG LINK OUT SIG LINK OUT XTP DTP XTP DTP 1 2 3 4...

Page 20: ...pairs reversed is a crossover cable A cable that is wired the same at both ends is called a straight through cable because no pin pair assignments are swapped 12345678 RJ 45 Connector Insert Twisted P...

Page 21: ...ase T Ethernet requires CAT 3 UTP or STP cable at minimum 100Base T Fast Ethernet requires CAT 5e UTP or STP cable at minimum For ports on an IPCP module see the IPCP Pro Series User Guide at www extr...

Page 22: ...ommunications network Ne connectez pas ces port des donn es informatiques ou un r seau de t l communications Do not use Extron UTP23SF 4 Enhanced Skew Free AV UTP cable or STP201 cable to link the mat...

Page 23: ...re Tip L R Sleeves Tip Ring Tip Ring L R Sleeves Tip Ring Tip Ring L R Sleeves Tip Sleeve Sleeve Tip L R Tip Jumper Gnd Sleeve Tip Ring Gnd Sleeve Unbalanced Mono Mic Input Balanced Mono Mic Input Fig...

Page 24: ...N MATRIX CONFIG VOLUME CONTROL MIC VOLUME I O AUDIO VIDEO ENTER PRESET VIEW ESC RTS CTS Tx Rx OVER LIMIT S 1 2 3 2 1 3 4 1 2 3 1 4 2 eBUS COM IR S I O RELAYS A Figure 17 Front Panel Configuration Port...

Page 25: ...re outputs an output can never be tied to more than one input Configuration is one or more ties one or more sets of ties or a combination 1 Press and release the Esc button to clear any input button o...

Page 26: ...input and output buttons 1 Press and release the Preset button PRESET PRESET 1 2 3 4 5 6 7 The Preset button lights Press and release All input and output buttons with assigned presets light red 2 Pr...

Page 27: ...button SELECT SELECT 1 2 3 4 5 6 7 LOGO LOGO The button lights Press and release Lit input buttons identify saved logo files INPUTS 2 Press and release the input button for the desired logo file 3 Th...

Page 28: ...re Lock mode 0 The front panel is completely unlocked Lock mode 1 All functions are locked from the front panel except for setting Lock mode 2 Some functions can be viewed Lock mode 2 Basic functions...

Page 29: ...O ENTER PRESET VIEW ESC CONTROL I O AUDIO VIDEO ENTER PRESET VIEW ESC CONTROL I O AUDIO VIDEO ENTER PRESET VIEW ESC Press and hold for 2 seconds Press and hold for 2 seconds Selecting Lock Mode 2 or T...

Page 30: ...ings IP address subnet mask user name and administrator or user password of the IPCP controller or switcher Establish a network connection as follows 1 Open a TCP socket to port 23 using the switcher...

Page 31: ...on your computer The simplest way to do this is to install the Product Configuration Software see Installing and Starting the Control Programs on page 28 and then run the Found New Hardware Wizard Ho...

Page 32: ...5 In7 Vid Tie input 7 video to output 5 Tie input X to output X audio X X Out X In X Aud Tie input X audio to output X Audio is broken away Example 2 4 Out4 In2 Aud Tie input 2 audio to output 4 Tie i...

Page 33: ...st Digital Sync Validation Processing DSVP List sync of all inputs 0LS X 1 X 2 X 3 X n Mulitple X s each is the signal status of an input starting from 1 n is the highest number of inputs for your swi...

Page 34: ...must be present have already been created in the DSP Configurator program to be available as X1 s for SIS commands Set gain or attenuation dB value E D X1 X1 GRPM GrpmD X1 X1 Specify for gain or for a...

Page 35: ...ee Setting the Front Panel Locks Executive Modes on page 20 for more information on the Lock modes Lock all front panel functions 1X Exe1 Set Lock mode 1 Lock advanced front panel functions 2X Exe2 Se...

Page 36: ...s of the switcher including creating video and audio ties saving logos Also provides control of audio line input gain and attenuation output attenuation and muting audio input format analog digital or...

Page 37: ...the Download tab see figure 1 The Find Software Downloads link appears 2 1 1 1 1 1 1 1 1 1 1 3 3 3 3 3 3 3 3 3 3 2 2 2 2 2 2 2 2 2 2 Figure 18 Find Software and Downloads 2 Click the Software 3 link...

Page 38: ...2 2 2 2 2 2 2 2 2 Figure 20 Device Discovery Screen TIP You can also launch the DSP Configurator program from the Product Configuration Software BUT PCS audio level controls can be locked out from wit...

Page 39: ...igure 22 Figure 22 DSP Configurator Screen and Device Selection TIP You can also launch the DSP Configurator program from within the Product Configuration Software 2 Select the DTP CrossPoint switcher...

Page 40: ...08 Selected NOTE The DSP Configurator has a software lock that protects the complex DSP audio adjustments making them unavailable for selection in PCS This protects the DSP settings against inadverten...

Page 41: ...version 8 0 or newer with compatibility mode off Mozilla Firefox version 6 or newer Google Chrome version 9 or newer Apple Safari version 4 or newer 2 Click in the Address field and enter the IP addre...

Page 42: ...words for all accounts on this device have been set to the device serial number In the event of a complete system reset the passwords convert to the default which is no password The switcher displays...

Page 43: ...irates Dubai This Limited Warranty does not apply if the fault has been caused by misuse improper handling care electrical or mechanical abuse abnormal operating conditions or if modifications were ma...

Page 44: ...Worldwide Headquarters Extron USA West 1025 E Ball Road Anaheim CA 92805 800 633 9876...