Figure 12: Job aid
To install the ESD discharge cable, perform this procedure.
1. Connect the ground lug on the ESD discharge cable to a safe and suitable earth ground.
2. Connect all RJ-45 cable connectors to the female RJ-45 connector of the ESD discharge
cable for at least 5 seconds, and then connect each RJ-45 cable connector to the switch.
3. Leave cables connected to the networking equipment. After you connect cables to
networking equipment, the cables do not build up charge.
Technical specifications
The following table provides the technical specifications for the individual switches in this series.
Ensure that the area where you install the switch and where it operates meets these requirements.
Warning:
To avoid bodily injury from hazardous electrical shock and current, never remove the top of
the device. No user-serviceable components are inside.
Table 5: Physical specifications
Specifications
8200
8400
Height
3.5 in. (88.9mm) — 2U
3.5 in. (88.9mm) — 2U
Width
17.5 in. (444.5 mm) - 19” rack
mountable
17.5 in. (444.5 mm) — 19” rack
mount compatible
Depth
19.68 in. (500 mm)
26.5 in. (673 mm)
Weight
32.1 lb (14.56 kg) VSP 8284XSQ
(EC8200x01-E6)
33.35 lb (15.13 kg) - Weight
includes fan modules only (no
Table continues…
Installing the Virtual Services Platform 8000 Series
December 2017
Installing the VSP 8000 Series
34