As default this charger will be set to typical user settings when it is connected to DC 11~18V for
the first time. The screen displays the following information in sequence and the user can change
the parameter on each screen.
If you need to alter the parameter value in the program, press “Start/Enter” key to make it blink
then change the value with “INC” or “DEC” key. The value will be stored by pressing
“Start/Enter” key once.
13
INC
DEC INC
INC
DEC
User setup starting screen.
The screen displays the nominal voltage of Lithium battery. There are three
kinds of Lithium battery: LiFe(3.3V), Lilo(3.6V) or LiPo(3.7V). This is very
important so you have to check the battery carefully and set it up correctly. If it
is different from correct value the battery may be exploded during charge
process.
X-605 recognize the cell count of Lithium battery automatically at the
beginning of charge or discharge process to avoid from erroneous setting by
user. But deeply discharged battery can be perceived incorrectly. To prevent
the error, you can set the time term to verify the cell count by the processor.
Normally, 10 minutes are enough to perceive the cell count correctly. For the
battery of larger capacity, you may extend the time term. But if you set the time
term to long for the battery of smaller capacity, the charge or discharge
process can be finished within the time term with the erroneous cell count. This
may cause the fatal result. If the processor recognizes the cell count
incorrectly at the beginning of charge or discharge process, you may extend
the time. Otherwise, you had better use with the default value.
INITIAL PARAMETER SETUP (USERS SET UP)