EPICenter Server Issues
EPICenter Concepts and Solutions Guide
169
2
Go to the EPICenter install directory:
cd /opt/extreme/epc5_0
3
Make sure the
LD_LIBRARY_PATH
environment variable is set to the EPICenter directory installation
directory:
setenv LD_LIBRARY_PATH /opt/extreme/epc5_0/database
4
Execute the following command:
database/dbeng9.exe -f basecamp.db
5
Watch the output from this command. If the database program indicates it cannot recover the database,
delete the database log:
rm basecamp.log
and try executing the previous command again:
database/dbeng9.exe -f basecamp.db
6
If the database is successfully recovered, restart the server.
If the database cannot be recovered, you will need to restore the database from a backup. See
Appendix C in the
EPICenter Reference Guide
for instructions on restoring the database from a backup.
EPICenter Server Issues
Problem: Cannot talk to a specific switch.
Verify that the switch is running ExtremeWare software version 2.0 or later.
Ping the switch's IP address to verify availability of a route. Use the
ping
command from a MS DOS or
Solaris command shell.
If the switch is using SNMPv1, verify that the read and write community strings used in EPICenter match
those configured on the switch. If the switch is using SNMPv3, verify that the SNMPv3 parameters
configured in EPICenter match those on the switch.
Problem: ExtremeWare CLI or ExtremeWare Vista changes are not reflected in EPICenter.
Verify that the switch is running ExtremeWare software version 2.0 or later.
From the Inventory Manager, click
Sync
to update the information from the switch. This refreshes the
switch specific data, validates the SmartTrap rules, and ensures that the EPICenter server is added as a
trap receiver (Extreme switches only).
If the problem persists, verify that the EPICenter workstation has been added in the list of trap
destinations on the given switch:
1
Telnet to the switch.
2
Log in to the switch.
3
Type
show management
to verify that the system running the EPICenter is a trap receiver, or
show snmpv3 target-addr <ipaddress>
if the device is running SNMPv3.
An Extreme switch can support a maximum of 6 trap destinations in ExtremeWare 2.0, and up to 16 trap
destinations with ExtremeWare 5.0 or greater. If EPICenter is not specified as a trap destination, then no
Summary of Contents for EPICenter 5.0
Page 12: ...12 EPICenter Concepts and Solutions Guide Preface...
Page 76: ...76 EPICenter Concepts and Solutions Guide Managing your Network Assets...
Page 92: ...92 EPICenter Concepts and Solutions Guide Managing VLANs...
Page 116: ...116 EPICenter Concepts and Solutions Guide Managing Wireless Networks...
Page 146: ...146 EPICenter Concepts and Solutions Guide VoIP and EPICenter Avaya Integrated Management...
Page 163: ...Appendices...
Page 164: ......
Page 178: ...178 EPICenter Concepts and Solutions Guide Troubleshooting...