Page 32
ALARMS
Display
Message
Cause
Solution
Indicates the presence of an alarm
This indicator lights up when one of the alarms described
below is in progress and is accompanied by the
corresponding indication on display D1. To reset the alarm,
press button 1 and hold for three seconds when the stove is
completely cold.
VENTOLA FUMI
The exhaust motor is blocked.
The speed control probe is faulty.
No power supply to the exhaust
motor.
All restore operations must be carried out by an
authorised technician.
SONDA FUMI
The exhaust fume probe is broken.
The
exhaust
fume
probe
is
disconnected from the board.
All restore operations must be carried out by an
authorised technician.
FUMI ELEVATI
The blower is faulty.
Excessive pellet feed.
No power supply to the fan.
Adjust the flow of pellets (see
“Pellet Feed Adjustment”).
Other restore operations must be carried out by an
authorised technician.
DEPRESSIONE
The exhaust pipe is obstructed.
The combustion chamber is dirty.
The pressure sensor is faulty.
The ash drawer is not closed properly.
The door is not closed properly.
Check to make sure that the exhaust outlet and the
combustion chamber are clean.
Check to see if the drawer is closed properly.
Check to see if the door is closed properly.
Other restore operations must be carried out by an
authorised technician.
MANCATA
FIAMMA
The pellet hopper is empty.
The spark plug is faulty or out of
position.
Inadequate pellet feed setting.
Check the level in the pellet hopper.
Check the procedures described in “
Lighting”.
Adjust the flow of pellets (see
“Pellet Feed Adjustment”)
Other restore operations must be carried out by an
authorised technician.
MANCATA
FIAMMA
BLAC OUT
No electricity during the lighting
phase.
Press button 1 to switch off the stove and repeat the
procedure described in “
Lighting”.
MANCANO
PELLET
The pellet hopper is empty.
Pellet feeding is insufficient.
The feed motor still has to settle in.
The gearmotor is not loading pellets.
Check the level in the pellet hopper.
Adjust the flow of pellets (see
“Pellet Feed Adjustment”)
Other restore operations must be carried out by an
authorised technician.
ATTESA
PULIZIA
+
allarme
An attempt is made to reset an alarm
white the stove is still cooling.
Whenever one of the alarms described above is tripped, the
stove automatically shuts down.
During this phase, any attempt to reset the alarm will be
blocked, and the display will show the alarm and ATTESA
PULIZIA in alternation.
Resetting the alarm by pressing button 1 is only possible
after the stove has completely shut down.
TEL
- - - - - - - - - -
Display
of
the
service
centre
telephone number.
When an alarm occurs, the type of alarm detected and the
telephone number of the service centre flash on the display
in alternation.
If the number has not been entered, the display shows a
series of dashes.
Summary of Contents for INSERTO COMFORT MINI
Page 1: ...PELLET STOVES Instruction Manual INSERTO COMFORT MINI ...
Page 2: ...Page 2 ...
Page 35: ...Page 35 13 WIRING DIAGRAM ...
Page 42: ...Page 42 Notes ...